Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Atypical Pneumonia DNA Panel, Qualitative,  Real-Time PCR

Atypical Pneumonia DNA Panel, Qualitative,  Real-Time PCR: Quest Diagnostics test 17610

Quest Diagnostics test 17610, CPT 87486, 87541, 87581, 87798. Specimen: 1 mL sputum or bronchial lavage/wash collected in a sterile, leak-proof plastic container or throat or nasopharyngeal sw.

Atypical Pneumonia DNA Panel, Qualitative,  Real-Time PCR is Quest Diagnostics test code 17610, billed with CPT 87486, 87541, 87581, 87798. Specimen: 1 mL sputum or bronchial lavage/wash collected in a sterile, leak-proof plastic container or throat or nasopharyngeal swab in M4 media or V-. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code17610
CPT87486, 87541, 87581, 87798
LOINC—
Specimen1 mL sputum or bronchial lavage/wash collected in a sterile, leak-proof plastic container or throat or nasopharyngeal swab in M4 media or V-C-M medium (green-cap) tube or equivalent (UTM)
Minimum volume0.35 mL sputum or bronchial lavage/wash
ContainerSterile leak-proof plastic container
Storage / transportRefrigerated (cold packs)

Methodology

Real-Time Polymerase Chain Reaction

Collection instructions

Respiratory samples in M4 media: Use sterile vials containing 3 mL of sterile M4 media. If using swabs, use only sterile Dacron® or Rayon swabs with plastic or wire shafts.. DO NOT use calcium alginate swabs, as they may contain substances that inhibit PCR testing. Break applicator sticks off near the tip to permit tightening of the cap. Sputum: Collect in a sputum collection kit or a sterile, plastic container with a leak-proof cap.. Bronchial lavage: Collect in a sterile container with a leak-proof cap.

Stability

TemperaturePeriod
Room temperature48 hours
Refrigerated7 days
Frozen30 days

Causes for rejection

Calcium alginate swabs

Reference range

See individual tests

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering. Please provide Service area information to confirm Test Code for the lab that services your account.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 87486, 87541, 87581

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation