Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Aldosterone:Renin Ratio

Aldosterone:Renin Ratio: Labcorp test 004354

Labcorp test 004354, CPT 82088, 84244. Specimen: Serum (refrigerated) and plasma (frozen). Turnaround: 4 - 7 days.

Aldosterone:Renin Ratio is Labcorp test code 004354, billed with CPT 82088, 84244. Specimen: Serum (refrigerated) and plasma (frozen). Turnaround time: 4 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code004354
CPT82088; 84244
LOINC1763-2, 2915-7, 30894-0, 55151-5
SpecimenSerum (refrigerated) and plasma (frozen)
Volume1 mL serum and 1 mL plasma
Minimum volume0.5 mL serum and 0.8 mL plasma ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube and lavender-top (EDTA) tube
Turnaround time4 - 7 days
Storage / transportSerum, refrigerated and plasma, frozen

Also known as: ARR

Test includes

Aldosterone, plasma renin activity (PRA)

Use

Screening test for primary aldosteronism in higher risk groups of hypertensive patients

Methodology

Liquid chromatography/tandem mass spectrometry (LC/MS-MS)

Collection instructions

Collect blood mid-morning, after the patient has been up (sitting, standing, or walking) for at least two hours and seated for 5 to 15 minutes. Refer to descriptions for individual tests Renin Activity, Plasma [002006] and Aldosterone, LC/MS [004374] for more detailed preparation and test collection information. After collection, immediately centrifuge the lavender-top tube at room temperature, transfer plasma to a transport tube, and freeze . Label this tube "Frozen Plasma−Renin." If a red-top tube is used, transfer separated serum to a plastic transport tube. Label the serum tube "Serum−Aldosterone." To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.

Patient preparation

Patients should be instructed to maintain an unrestricted dietary salt intake prior to testing. Washout of all interfering antihypertensive medications may be considered in patients with mild hypertension but is potentially problematic in others and perhaps unnecessary in that medications with minimal effect on the ARR can be used in their place. The patient should not take drugs that markedly affect the ARR for at least four weeks prior to blood collection. These drugs include: • Spironolactone, eplerenone, amiloride, and triamterene • Potassium-wasting diuretics • Products derived from licorice root (e.g., confectionary licorice, chewing tobacco) More details can be found in the Endocrine Society clinical practice guideline.

Reference range

0.0−30.0 ng/dL per ng/mL/hour

Limitations

A number of factors can affect the aldosterone:renin ratio and thus lead to false-positive or false-negative results. These include: Factors producing falsely decreased ARR (false negative) • Potassium-wasting diuretics • Potassium-sparing diuretics • Angiotensin-converting enzyme (ACE) inhibitors • Angiotensin II type 1 receptor blockers (ARBs) • Calcium blockers, dihydropyridines (DHPs) • Hypokalemia • Sodium restricted • Pregnancy • Renovascular hypertension • Malignant hypertension Factors producing falsely increased ARR (false positive) • β-adrenergic blockers • Central α 2 -agonists (e.g., clonidine, α-methyldopa) • Nonsteroidal anti-inflammatory drugs (NSAIDs) • Renin inhibitors •…

LOINC map

Result codeResult nameUnitsResult LOINC
004372Aldosteroneng/dL1763-2
002007Renin Activity, Plasmang/mL/hr2915-7
004359Aldos/Renin Ratio30894-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82088, 84244

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation