Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Aldosterone, 24-Hour Urine

Aldosterone, 24-Hour Urine: Labcorp test 004291

Labcorp test 004291, CPT 82088. Specimen: Urine (24-hour). Turnaround: 4 - 9 days.

Aldosterone, 24-Hour Urine is Labcorp test code 004291, billed with CPT 82088. Specimen: Urine (24-hour). Turnaround time: 4 - 9 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code004291
CPT82088
LOINC1764-0, 1765-7
SpecimenUrine (24-hour)
Volume10 mL
Minimum volume1 mL ( Note: This volume does not allow for repeat testing.)
ContainerPlastic urine container, no preservative
Turnaround time4 - 9 days
Storage / transportRefrigerate

Use

Study of adrenocortical-renin-angiotensin system; adrenal cortical function test; evaluate renal hypertension; diagnose Conn syndrome (primary aldosteronism); evaluate hypokalemia with hypertension

Methodology

Liquid chromatography/tandem mass spectrometry (LC/MS-MS)

Collection instructions

Instruct the patient to void at 8 a.m. and discard the specimen. Then collect all urine including the final specimen voided at the end of the 24-hour collection period (i.e., 8 a.m. the next morning) into the plastic urine container. Screw the lid on securely. Transport the specimen promptly to the laboratory. Container must be labeled with patient's full name, date and time collection started, and date and time collection finished. pH must be 4 to 8.

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Patient preparation

If patient is taking diuretics, antihypertensive drugs, cyclic progestational agents, estrogen, or licorice, results for aldosterone may not be interpretable. Patient should be on a diet containing 135 mmol (3 g) sodium per day for at least two weeks and preferably 30 days prior to testing.

Causes for rejection

Incomplete 24-hour collection; original container with pH <2

Reference range

• Pediatric: − 0 to 3 days: 0.00−5.00 μg/24 hours − 4 days to 10 years: 0.00−8.00 μg/24 hours − >10 years: 0.00−19.00 μg/24 hours • Adults: − Low sodium intake: 20.00−80.00 μg/24 hours − Normal sodium intake: 0.00−19.00 μg/24 hours − High sodium intake: 0.00−12.00 μg/24 hours

Special instructions

Instructions for suppression/stimulation tests that involve serum aldosterone measurement can be found in the online Endocrine Appendix: Aldosterone Suppression.

Limitations

Urinary aldosterone measurements alone are of limited value in the diagnosis of hyperaldosteronism. Elevated levels mandate further investigation. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
Aldosterone U,Randomug/L1764-0
Aldosterone,U, Timedug/24 hr1765-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82088

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.