Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Aldosterone, LC/MS

Aldosterone, LC/MS: Labcorp test 004374

Labcorp test 004374, CPT 82088. Specimen: Serum or plasma. Turnaround: 4 - 7 days.

Aldosterone, LC/MS is Labcorp test code 004374, billed with CPT 82088. Specimen: Serum or plasma. Turnaround time: 4 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code004374
CPT82088
LOINC1763-2
SpecimenSerum or plasma
Volume1.2 mL
Minimum volume1 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube, gel-barrier tube, or lavender-top (EDTA) tube
Turnaround time4 - 7 days
Storage / transportRefrigerate.

Use

Evaluate patients with hypertension and possible hyperaldosteronism

Methodology

Liquid chromatography/tandem mass spectrometry (LC/MS-MS)

Collection instructions

If a tube other than gel-barrier is used, transfer separated serum or plasma to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature3 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Patient preparation

In order to facilitate interpretation of test results, the patient should be taken off medications for at least three weeks prior to sample collection. Dietary sodium levels during the period prior to testing can affect aldosterone levels. Reference intervals are based on the clinician's verification that the patient has been on a normal sodium diet. Since patient posture prior to collection affects aldosterone levels, it is recommended that the patient be ambulatory for at least 30 minutes before blood collection. If inpatients are physically able, they should be asked to ambulate for 30 minutes before blood is drawn for aldosterone. Reference intervals are provided for patients who have ambulated for at least 30 minutes prior to collection (standing patients).

Causes for rejection

Gross hemolysis; gross lipemia

Reference range

• Premature infant: − 26 to 28 weeks, day 4: 5.0−635.0 ng/dL − 31 to 35 weeks, day 4: 19.0−141.0 ng/dL • Full-term infant: − 3 days: 7.0−184.0 ng/dL − 7 days: 5.0−175.0 ng/dL − 1 to 11 months: 5.0−90.0 ng/dL − 1 year: 7.0−54.0 ng/dL − 2 to 9 years: 5.0−80.0 ng/dL − 10 to 14 years: 4.0−48.0 ng/dL − >14 years: 0.0−30.0 ng/dL

Special instructions

Instructions for suppression/stimulation tests that involve serum aldosterone measurement can be found in the online Endocrine Appendices: Dexamethasone Suppression and ACTH Stimulation. Also, refer to the online Endocrine Appendix: Multiple-specimen Testing for instructions.

Limitations

Decreased perfusion of the kidneys leads to increased aldosterone and renin. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
004372Aldosteroneng/dL1763-2

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82088

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation