Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Venous Thrombosis Hypercoagulability Panel with Reflex

Venous Thrombosis Hypercoagulability Panel with Reflex: Quest Diagnostics test 11475

Quest Diagnostics test 11475, CPT 81240, 85240, 85300, 85303, 85305, 85306, 85307, 85613, 85730, 86146, 86147. Specimen: 5 mL whole blood collected in an EDTA (lavender-top) tube and.

Venous Thrombosis Hypercoagulability Panel with Reflex is Quest Diagnostics test code 11475, billed with CPT 81240, 85240, 85300, 85303, 85305, 85306, 85307, 85613, 85730, 86146, 86147. Specimen: 5 mL whole blood collected in an EDTA (lavender-top) tube and. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, Allina Health Laboratory (Abbott Northwestern), Cleveland Clinic Laboratories, ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code11475
CPT85307, 81240, 85303, 85306, 85305, 85300, 86147 (x2), 85240, 86146 (x2), 85730, 85613
LOINC—
Specimen5 mL whole blood collected in an EDTA (lavender-top) tube and 1 mL frozen platelet-poor plasma collected in each of six 3.2% sodium citrate (light blue-top) tubes
Minimum volume3 mL whole blood • 0.5 mL (x6) frozen platelet-poor plasma
ContainerEDTA (lavender-top) tube and Transport tube(s)
Storage / transportWhole blood: Room temperature Plasma: Frozen

Methodology

Chromogenic Clotting Assay • Enzyme Immunoassay (EIA) • Immunoturbidimetric Immunoassay • Polymerase Chain Reaction and Detection

Collection instructions

Whole blood sample is for the Factor V Mutation Analysis and Prothrombin (Factor II) Mutation Analysis. Platelet-poor plasma is for remaining tests. Platelet-poor plasma: Centrifuge light blue-top tube 15 minutes at approximately 1500 x g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into six plastic vials. Plasma must be free of platelets (<10,000/mcL). Freeze immediately and ship on dry ice. Note: Storage of whole blood at refrigerated temperatures prior to processing may lead to cryoprecipitate formation and falsely low Factor VIII and von Willebrand Factor studies.

Stability

⁠⁠⁠⁠⁠⁠⁠Whole blood Room temperature: 8 days Refrigerated: 8 days Frozen: 30 days Plasma Room temperature: Unacceptable Refrigerated: Unacceptable Frozen: 14 days

Causes for rejection

See individual tests

Reference range

See Laboratory Report

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 81240, 85240, 85300

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation