Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Venous Thrombosis Hypercoag Panel w/Reflex, Consultation (Warfarin Patient)

Venous Thrombosis Hypercoag Panel w/Reflex, Consultation (Warfarin Patient): Quest Diagnostics test 19655

Quest Diagnostics test 19655, CPT 80503, 80504, 80505, 80506, 81240, 83090, 85240, 85300, 85307, 85598, 85613, 86146, 86147. Specimen: 5 mL whole blood collected in EDTA (lavender-top) tube and.

Venous Thrombosis Hypercoag Panel w/Reflex, Consultation (Warfarin Patient) is Quest Diagnostics test code 19655, billed with CPT 80503, 80504, 80505, 80506, 81240, 83090, 85240, 85300, 85307, 85598, 85613, 86146, 86147. Specimen: 5 mL whole blood collected in EDTA (lavender-top) tube and. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code19655
CPT81240, 85307, 85300, 85240, 83090, 86147 (x2), 86146 (x2), 85598, 85613, Dependent on the complexity of the consultation, 80503 or 80504 or 80505 may be assigned. 80506 may also be billed if high complexity with more than 60 minutes of time spent for the consultation.
LOINC—
Specimen5 mL whole blood collected in EDTA (lavender-top) tube and 1 mL frozen platelet-poor plasma collected in each of six 3.2% sodium citrate (light blue-top) tubes and 1 mL serum
Minimum volume3 mL whole blood • 0.5 mL (x6) frozen platelet-poor plasma • 0.6 mL serum
ContainerEDTA (lavender-top) tube and Transport tube(s)
Storage / transportWhole blood and serum: Room temperature Plasma: Frozen

Methodology

See individual tests

Collection instructions

Whole blood sample is for the Factor V Mutation Analysis and Prothrombin (Factor II) Mutation Analysis. Serum sample is for the Homocysteine. Red-top tubes: Place the specimen in a refrigerator or ice bath for 30 minutes after collection. Centrifuge the specimen as soon as possible after complete clot formation has taken place. Transfer the serum to a plastic screw-capped vial. Barrier gel separator tubes: Place the specimen in a refrigerator for 30 minutes after collection. Centrifuge the specimen as soon as possible after complete clot formation has taken place. Do not place barrier tubes in an ice bath as freezing may prevent the barrier gel from adequately separating serum from cells. Platelet-poor plasma is for the remaining tests. Platelet-poor plasma: Please submit a separate, frozen vial for each special coagulation assay ordered. Draw blood in a light blue-top tube containing 3.2% sodium citrate, mix gently by inverting 3-4 times. Centrifuge 15 minutes at 1500 g within one hour of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial(s). Freeze immediately and transport on dry ice. Note: Storage of whole blood at refrigerated temperatures prior to processing may lead to cryoprecipitate formation and falsely low Factor VIII and von Willebrand Factor studies.

Stability

Whole blood Room temperature: 8 days Refrigerated: 8 days Frozen: 30 days Serum Room temperature: 4 days Refrigerated: 14 days Frozen: 6 months Plasma Room temperature: Unacceptable Refrigerated: Unacceptable Frozen: 14 days

Causes for rejection

See individual tests

Reference range

See Laboratory Report

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

Prothrombin (Factor II) 20210G→A Mutation Analysis: This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 80503, 80504, 80505

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation