Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Recurrent Miscarriage Evaluation/Coagulation Panel with Consultation

Recurrent Miscarriage Evaluation/Coagulation Panel with Consultation: Quest Diagnostics test 19671

Quest Diagnostics test 19671, CPT 80503, 80504, 80505, 80506, 81240, 81241, 83090, 83516, 85300, 85303, 85306, 85613, 85730, 86146, 86147. Specimen: 5 mL whole blood collected in an EDTA (lavender-top) tube and.

Recurrent Miscarriage Evaluation/Coagulation Panel with Consultation is Quest Diagnostics test code 19671, billed with CPT 80503, 80504, 80505, 80506, 81240, 81241, 83090, 83516, 85300, 85303, 85306, 85613, 85730, 86146, 86147. Specimen: 5 mL whole blood collected in an EDTA (lavender-top) tube and. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code19671
CPT83090, 85300, 85303, 85306, 85613, 85730, 83516 (x2), 86146 (x3), 86147 (x3), 81240, 81241, Dependent on the complexity of the consultation, 80503 or 80504 or 80505 may be assigned. 80506 may also be billed if high complexity with more than 60 minutes of time spent for the consultation.
LOINC—
Specimen5 mL whole blood collected in an EDTA (lavender-top) tube and 1 mL frozen platelet-poor plasma collected in each of four 3.2% sodium citrate (light blue-top) tubes and 3 mL frozen serum collected in a red-top tube (no gel)
Minimum volume3 mL whole blood • 0.5 mL plasma, each specimen • 0.5 mL serum
ContainerTransport tube(s)
Storage / transportWhole blood: Room temperature Plasma and serum: Frozen

Methodology

Chromogenic • Clotting Assay • Enzyme Immunoassay (EIA) • Immunoassay (IA) • Immunoturbidimetric • Polymerase Chain Reaction & Detection

Collection instructions

Whole blood sample is for the Factor V Mutation Analysis and Prothrombin (Factor II) Mutation Analysis. Serum sample is for the Homocysteine. Red-top tubes: Place the specimen in a refrigerator or ice bath for 30 minutes after collection. Centrifuge the specimen as soon as possible after complete clot formation has taken place. Transfer the serum to a plastic screw-capped vial. Barrier gel separator tubes: Place the specimen in a refrigerator for 30 minutes after collection. Centrifuge the specimen as soon as possible after complete clot formation has taken place. Do not place barrier tubes in an ice bath as freezing may prevent the barrier gel from adequately separating serum from cells. Platelet-poor plasma is for remaining tests. Platelet-poor plasma: Centrifuge light blue-top tube 15 minutes at approximately 1500 x g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into four plastic vials. Plasma must be free of platelets (<10,000/mcL). Freeze immediately and ship on dry ice. Serum and plasma must remain frozen during storage and shipment. All requests for coagulation assays should include a brief patient history and other pertinent clinical information.

Stability

Whole blood Room temperature: 8 days Refrigerated: 8 days Frozen: 30 days Plasma Room temperature: Unacceptable Refrigerated: Unacceptable Frozen: 14 days Serum Room temperature: 4 days Refrigerated: 14 days Frozen: 6 months

Causes for rejection

Gross hemolysis • Grossly lipemic

Reference range

See Laboratory Report

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

Prothrombin (Factor II) 20210G→A Mutation Analysis and Factor V (Leiden) Mutation Analysis: This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 80503, 80504, 80505

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation