Measles (Rubeola) Virus Antibody, IgG: Michigan Medicine Laboratories (MLabs) test ROBG
Michigan Medicine Laboratories (MLabs) test ROBG, CPT 86765. Specimen: 0.5 mL serum. Turnaround: 24 hours.
Also known as: Measles Antibody IgG; Viral Antibody: Rubeola IgG; MMR Vaccine Response
Use
Support the diagnosis of measles or SSPE (sub-sclerosing pan ecephalitis) infection. The presence of IgG antibody generally indicates past exposure and immunity. The presence of IgM antibody or a fourfold or greater rise in IgG antibodies in paired sera indicates recent infection. Single IgG levels are not useful for supporting the diagnosis of an acute infection. Elevated levels in neonates should be followed up with studies to rule out the presence of maternal antibodies by demonstrating the absence of an IgM response.
Collection instructions
Collect specimen in SST tube. Centrifuge, aliquot serum into a plastic vial and refrigerate up to 7 days. Post-vaccination samples should be collected 4-6 weeks from the date of vaccination.
Reference range
Negative: No Rubeola IgG Antibody detected. Patient is presumed not to have previous exposure through infection or vaccination. Equivocal result; obtain an additional sample for re-testing. Positive: Rubeola IgG Antibody detected. Patient was exposed through infection or vaccination.
Limitations
A single elevated serum sample cannot be considered diagnostic of SSPE (sub-sclerosing pan ecephalitis). While cases of SSPE may have responses of 10 - 100X those generally seen, the best indicator is the detection of elevated levels of IgG specific for rubeola antigens in CSF as compared to those found in serum, suggesting local IgG production in CSF. In persons with normal immune systems, postinfectious encephalitis has no accompanying enhanced antibody response. Increasing titers of serum antibodies to rubeola virus, as well as other viruses (rubella), have been associated with active chronic hepatitis, systemic lupus erythematosus and infectious mononucleosis. The performance…
Section
Immunology
Performed
Monday - Friday
NY State approved
No
Alternate specimens
Red top tube. Plasma, EDTA or heparinized, is acceptable.
Performing Laboratory
Immunology & Special Chemistry
View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29
Other tests billed with CPT 86765
- Acute Measles Panel, IgM Antibody and PCR
- Encephalitis Antibody Panel, CSF
- Encephalitis Panel With Reflex to Herpes Simplex Virus Types 1 and 2 Glycoprotein G-Specific Antibodies, IgG, CSF
- Encephalitis Panel With Reflex to Herpes Simplex Virus Types 1 and 2 Glycoprotein G-Specific Antibodies, IgG, Serum
- Measles (Rubeola) Antibodies, IgG
- Measles (Rubeola) Antibodies, IgG and IgM
- Measles (Rubeola) Antibodies, IgM
- Measles (Rubeola) Antibodies, IgM
- Measles (Rubeola) Antibody, IgG
- Measles (Rubeola) Antibody, IgG, CSF
- Measles (Rubeola) Antibody, IgM
- Measles (Rubeola) Antibody, IgM by IFA
- Measles (Rubeola) Antibody, IgM, CSF by IFA
- Measles IgG Antibody
- Measles, Mumps, Rubella (MMR) Immunity Profile
- MMRV Immunity
- Occupation Screen - MMR/VZV Antibody Assessment Panel, IgG
- Rubeola immune status
- Measles (Rubeola) Antibodies, IgG and IgM, CSF
Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.