Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Occupation Screen - MMR/VZV Antibody Assessment Panel, IgG

Occupation Screen - MMR/VZV Antibody Assessment Panel, IgG: ARUP Laboratories test 2011375

ARUP Laboratories test 2011375, CPT 86735, 86762, 86765, 86787. Specimen: Serum separator tube.. Turnaround: Within 24 hours.

Occupation Screen - MMR/VZV Antibody Assessment Panel, IgG is ARUP Laboratories test code 2011375, billed with CPT 86735, 86762, 86765, 86787. Specimen: Serum separator tube.. Turnaround time: Within 24 hours. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code2011375
CPT86765; 86735; 86762; 86787
LOINC7962-4, 7966-5, 8014-3, 8047-3
SpecimenSerum separator tube.
Turnaround timeWithin 24 hours
Storage / transportRefrigerated.

Use

Use only to provide evidence of vaccination or prior infection by measles, mumps, rubella and varicella-zoster viruses.

Methodology

Semi-Quantitative Chemiluminescent Immunoassay (CLIA)

Collection instructions

Separate serum from cells ASAP or within 2 hours of collection. Transfer 1.0 mL serum to an ARUP standard transport tube. (Min: 0.5 mL)

Stability

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year

Causes for rejection

Body fluid, CSF, plasma or urine specimens. Contaminated, heat-inactivated, hemolyzed, lipemic, or severely icteric specimens.

Reference range

Test Number Components Reference Interval Measles Virus (Rubeola) Antibody IgG 13.4 AU/mL or less Negative - No significant level of Measles (Rubeola) IgG antibody detected. This result is not consistent with vaccination (could indicate lack of immune response to vaccination) or exposure to Measles (Rubeola). 13.5-16.4 AU/mL Equivocal - Repeat testing in 7-14 days may be helpful to demonstrate IgG seroconversion. 16.5 AU/mL or greater Positive - IgG antibody to Measles (Rubeola) detected. This result is consistent with vaccination or exposure to Measles (Rubeola). Mumps Virus Antibody IgG 8.9 AU/mL or less Negative - No significant level of Mumps IgG antibody detected. This result is not consistent with vaccination (could indicate lack of immune response to vaccination) or exposure to Mumps. 9.0-10.9 AU/mL Equivocal - Repeat testing in 7-14 days may be helpful to demonstrate IgG seroconversion. 11.0 AU/mL or greater Positive - IgG antibody to Mumps detected. This result is consistent with vaccination or exposure to Mumps. Rubella Virus Antibody IgG 8.9 IU/mL or less Negative - No significant level of Rubella IgG antibody detected. This result is not consistent with vaccination (could indicate lack of immune response to vaccination) or exposure to Rubella. 9-9.9 IU/mL Equivocal - Repeat testing in 7-14 days may be helpful to demonstrate IgG seroconversion 10 IU/mL or greater …

Performed

Sun-Sat

Compliance Category

FDA

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
2011396Measles Virus (Rubeola) Antibody IgG7962-4
2011397Mumps Virus Antibody IgG7966-5
2011398Rubella Virus Antibody IgG8014-3
2011399Varicella-zoster Virus Ab IgG8047-3

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 86735, 86762, 86765

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation