Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › Rubeola immune status

Rubeola immune status: Allina Health Laboratory (Abbott Northwestern) test 1812

Allina Health Laboratory (Abbott Northwestern) test 1812, CPT 86765. Specimen: Serum. Turnaround: 1 - 3 days.

Rubeola immune status is Allina Health Laboratory (Abbott Northwestern) test code 1812, billed with CPT 86765. Specimen: Serum. Turnaround time: 1 - 3 days. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Labcorp, Quest Diagnostics, ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code1812
CPT86765
LOINC—
SpecimenSerum
Volume1.0 mL
ContainerGold serum separator (SST) tube
Turnaround time1 - 3 days

Also known as: Measles; Rubeola IgG antibody

Methodology

Chemiluminescence Immunoassay (CLIA)

Collection instructions

Immediately following collection, thoroughly mix sample by gently inverting 5 times

Stability

Refrigerated (preferred) - 7 days Ambient - 24 hours Frozen (OK)

Causes for rejection

Improper labels (unlabeled or mislabeled) Hemolysis (some procedures) Improper anticoagulant or ratio Delay in transport Improper storage temperature affecting results Improper container Leaking container resulting in compromised specimen Quantity not sufficient (QNS)

Reference range

Negative: <13.5 Index Value (Presumed not immune) Equivocal: 13.5 - 16.4 Index Value (Repeat in 1 - 2 wks) Positive: >16.5 Index Value (Presumed immune)

Performed

Mo - Fr

Abbreviation

RBA

Order number

86765.0

Alternate container

Red serum vial/tube - 5 mL Red/grey serum separator (SST) vial/tube, 10 mL Alternate processing instructions: Allow sample to clot Spin Transfer serum to a False bottom plasma/serum transport vial/tube (AHL), labelled as serum, within two (2) hours of sample collection Alternate transport container: False bottom plasma/serum transport vial/tube (AHL) Red/grey serum separator (SST) vial/tube, 10 mL

Transport container

Gold serum separator (SST) tube

Performing Laboratory

AHL - Immunology: I

Processing instructions

Allow sample to clot for a minimum of 30 minutes Spin within two (2) hours of sample collection

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 86765

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation