Acute Measles Panel, IgM Antibody and PCR: Labcorp test 160077
Labcorp test 160077, CPT 86765, 87638. Specimen: Serum and throat or NP swab. Turnaround: 4 - 6 days.
Also known as: Rubeola
Test includes
This test includes Measles (Rubeola) Antibodies, IgM; and Measles (Rubeola), PCR, Swab.
Use
This test is used as a guideline-aligned laboratory diagnosis of acute measles virus infection in patients presenting with febrile rash illness and clinically compatible measles symptoms.
Methodology
Chemiluminescence immunoassay (CLIA) and Polymerase Chain Reaction (PCR)
Collection instructions
Serum: If tube other than a gel-barrier tube is used, transfer serum to a plastic transport tube. Swab: Throat specimen (preferred): Collect the specimen by swabbing the posterior pharynx. Nasopharyngeal swab: Collect the NP swab using standard techniques.
Stability
| Temperature | Period |
|---|---|
| Room temperature | Serum: 14 days |
| Swab: Unstable | Refrigerated |
| Serum: 14 days | Swab: 7 days |
| Frozen | Serum: 14 days |
| Swab: 14 days | Temperature |
| Period | Room temperature |
| Unstable | Refrigerated |
| Serum: 7 days | Swab: 7 days |
| Frozen | Serum: 6 month s |
| Swab: 14 days | Temperature |
| Period | Room temperature |
| Serum: 14 days | Swab: Unstable |
| Refrigerated | Serum: 14 days |
| Swab: 7 days | Frozen |
| Serum: 14 day s | Swab: 14 days |
Causes for rejection
Improperly submitted specimens; grossly hemolyzed, lipemic and icteric samples; heat-inactivated samples; samples with visible particulate matter or gross bacterial contamination; specimen not received in an approved VTM/UTM; swabs received in Liquid Amies (E-Swabs) or other bacterial swabs; specimens received without a swab; grossly leaking specimens; specimens received outside the stated stability
Limitations
A negative test does not rule out infection with measles virus. Results should be interpreted in conjunction with clinical finding. The absence of IgM-class antibodies suggests lack of an acute phase infection with measles virus. However, serology may be negative for IgM-class antibodies in early disease, and results should be interpreted in the context of clinical findings. Testing for IgM-class antibodies to measles should be limited to patients with clinically compatible disease. Specimens should be collected as soon as possible after the development of rash to maximize the sensitivity of measles RNA detection. Improperly collected samples may result in false negative results. PCR assays…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 160177 | Measles IgM, Serum | 21503-8 | |
| 140471 | Measles RNA, Swab | 91077-8 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 86765, 87638
- Encephalitis Panel With Reflex to Herpes Simplex Virus Types 1 and 2 Glycoprotein G-Specific Antibodies, IgG, CSF
- Encephalitis Panel With Reflex to Herpes Simplex Virus Types 1 and 2 Glycoprotein G-Specific Antibodies, IgG, Serum
- Measles (Rubeola) Antibodies, IgG
- Measles (Rubeola) Antibodies, IgG and IgM
- Measles (Rubeola) Antibodies, IgM
- Measles (Rubeola) Antibody, IgG
- Measles (Rubeola) Antibody, IgG, CSF
- Measles (Rubeola) Antibody, IgM
- Measles (Rubeola) Antibody, IgM by IFA
- Measles (Rubeola) Antibody, IgM, CSF by IFA
- Measles IgG Antibody
- Measles, Mumps, Rubella (MMR) Immunity Profile
- MMRV Immunity
- Occupation Screen - MMR/VZV Antibody Assessment Panel, IgG
- Measles (Rubeola), PCR, Swab
- Measles (Rubeola), PCR, Urine
- Measles Virus by Qualitative NAAT
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation