Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Mixing Study, Inhibitor Screen

Mixing Study, Inhibitor Screen: Michigan Medicine Laboratories (MLabs) test MIXST

Michigan Medicine Laboratories (MLabs) test MIXST, CPT 85610, 85730. Specimen: 2 full 2.7mL tubes or 2mL of plasma (two 1mL aliquots). Turnaround: 2 hours.

Mixing Study, Inhibitor Screen is Michigan Medicine Laboratories (MLabs) test code MIXST, billed with CPT 85610, 85730. Specimen: 2 full 2.7mL tubes or 2mL of plasma (two 1mL aliquots). Turnaround time: 2 hours. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories, Cleveland Clinic Laboratories, Allina Health Laboratory (Abbott Northwestern).
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeMIXST
CPT85610, 85730
LOINC—
Specimen2 full 2.7mL tubes or 2mL of plasma (two 1mL aliquots)
Volume2 full 2.7mL tubes or 2mL of plasma (two 1mL aliquots)
Turnaround time2 hours
Storage / transportRoom temperature for whole blood or frozen aliquot of citrated plasma.

Also known as: Circulating Anticoagulant; Mixing Study; APTT, Prolonged; Evaluation of Prolonged PTT; Prolonged PTT Evaluation

Use

To determine reason for prolongation of the PT7 and/or aPTT test. Help to differentiate between a factor deficiency or coagulation inhibitor.

Collection instructions

Collect specimen in two blue top (citrate 3.2%) tubes. Mix by inversion. Specimen should arrive at lab within 3 hours of collection; transport at room temperature. Alternatively, centrifuge, aliquot plasma into two plastic tubes, and freeze the specimen within 4 hours of collection. Transport frozen specimen on dry ice. Collection of the blood through lines that have been previously flushed with heparin should be avoided. If the blood must be drawn through a VAD (vascular access device), the line should be flushed with 5 mL of saline and the first 5 mL of blood or six dead space volumes of the VAD discarded.

Reference range

Physician interpretation included.

Limitations

Performed only when APTT and PT are above the reference range. Test will not be performed if the patient is being treated with heparin, low molecular weight heparin, fondaparinux, coumadin, or a direct thrombin inhibitor (argatroban, dabigatran,bivalirudin, etc); reorder the Mixing Study two weeks after coumadin is discontinued or 48 hours after the heparins or thrombin inhibitors are discontinued.

Section

Coagulation

Performed

Daily, 24 hours

NY State approved

No

Performing Laboratory

Clinical Core Laboratory

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 85610, 85730

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation