Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Inhibitor Assay, PT with Reflex to PT 1:1 Mix

Inhibitor Assay, PT with Reflex to PT 1:1 Mix: ARUP Laboratories test 2003260

ARUP Laboratories test 2003260, CPT 85610, 85611. Specimen: Lt. blue (sodium citrate). Refer to Specimen Handling at aruplab.com for hemostasis/thrombosis specimen handling guideli. Turnaround: 1-2 days.

Inhibitor Assay, PT with Reflex to PT 1:1 Mix is ARUP Laboratories test code 2003260, billed with CPT 85610, 85611. Specimen: Lt. blue (sodium citrate). Refer to Specimen Handling at aruplab.com for hemostasis/thrombosis specimen handling guidelines.. Turnaround time: 1-2 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code2003260
CPT85610; if reflexed, add 85611
LOINC93321-8
SpecimenLt. blue (sodium citrate). Refer to Specimen Handling at aruplab.com for hemostasis/thrombosis specimen handling guidelines.
Turnaround time1-2 days
Storage / transportCRITICAL FROZEN. Separate specimens must be submitted when multiple tests are ordered.

Also known as: PT 1:1 Mix; PT Correction; PT Inhibitor Assay; PT Mixing Study; Circulating Anticoagulant; Prothrombin Time 1:1 Mix; Prothrombin Time Inhibitor Assay; Prothrombin Time Mixing Study; Protime Correction

Use

Initial screen for inhibitor in plasma.

Methodology

Electromagnetic Mechanical Clot Detection

Collection instructions

Transport 1 mL plasma. (Min: 0.5 mL)

Stability

Ambient: 24 hours; Refrigerated: Unacceptable; Frozen: 2 weeks

Causes for rejection

Serum. EDTA plasma, clotted or hemolyzed specimens.

Reference range

Test Number Components Reference Interval PT, Inhibitor Screen 12.0-15.5 seconds

Performed

Sun-Sat

Compliance Category

Standard

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
2003261PT, Inhibitor Screen93321-8

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 85610, 85611

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation