Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to HIV-1 GenoSure PRIme® or GenoSure Archive®: Labcorp test 550920
Labcorp test 550920, CPT 87536. Specimen: Plasma and whole blood. Turnaround: 14 - 19 days.
Also known as: HIV-1 Plasma Viremia; HiV-1 RNA Real-time PCR, Quantitative; Reflex to GenoSure Archive®; Reflex to GenoSure PRIme®; Viral Load
Use
This test is used to detect and measure HIV-1 in plasma with reflex to GenoSure PRIme® if viral load is greater than or equal to 500 copies/mL or reflex to GenoSure Archive® if viral load is less than 500 copies/mL. The GenoSure PRIme® and GenoSure Archive® assays detect mutations in the HIV viral genes that encode for HIV protease, reverse transcriptase and integrase. Mutations in these genes have been associated with resistance to antiretroviral drugs. D etect and measure HIV-1 in plasma with reflex to GenoSure PRIme® if viral load is greater than or equal to 500 copies/mL or reflex to GenoSure Archive® if viral load is less than 500 copies/mL. The GenoSure PRIme® and GenoSure Archive®…
Methodology
Cobas® AmpliPrep/Cobas® TaqMan® HIV-1 Test, Version 2.0 and polymerase chain reaction (PCR) amplification and DNA sequencing
Collection instructions
Both frozen plasma and frozen whole blood are required for this profile. Draw three lavender-top (EDTA) tubes. Do not use green-top (heparin) tubes. Plasma: Centrifuge two tubes within six hours of collection. Remove plasma, transfer plasma to screw-cap polypropylene transport tubes (not "pop-top" or "snap-cap"), and freeze. Ship specimen frozen. Whole blood: Do not centrifuge. Freeze tube immediately after draw. Ship specimen frozen. To avoid delays in turnaround time, when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.
Stability
Frozen: 6 weeks
Causes for rejection
Insufficient volume; heparinized plasma; specimen not frozen
Special instructions
If reflex test is performed, additional charges/CPT code(s) may apply.
Limitations
This procedure should only be used for patients with a documented HIV-1 infection.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 550445 | HIV-1 RNA by PCR | copies/mL | 20447-9 |
| 550446 | log10 HIV-1 RNA | log10copy/mL | 29541-0 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 87536
- HIV-1 RNA by PCR, Quantitative
- Human Immunodeficiency Virus 1 (HIV-1) by Quantitative NAAT with Reflex to HIV-1 Drug Resistance by Next Generation Sequencing
- Human Immunodeficiency Virus 1 (HIV-1) by Quantitative NAAT, CSF
- Human Immunodeficiency Virus 1 (HIV-1) by Quantitative NAAT, Plasma
- Human Immunodeficiency Virus 1 (HIV-1) RNA, Quantitative PCR, Plasma
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical)
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to HIV-1 GenoSure PRIme®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to HIV-1 GenoSure® MG
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to HIV-1 PhenoSense GT® Plus Integrase
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to PhenoSense Entry®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to PhenoSense GT®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to PhenoSense Integrase®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to PhenoSense®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to Trofile®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical)
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to HIV-1 GenoSure PRIme®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to HIV-1 GenoSure PRIme® or GenoSure Archive®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to HIV-1 GenoSure® MG
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to HIV-1 PhenoSense GT® Plus Integrase
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to PhenoSense Entry®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to PhenoSense GT®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to PhenoSense Integrase®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to PhenoSense®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to Trofile®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, RNA (Abbott® RealTime)
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation