Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to PhenoSense GT®

Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to PhenoSense GT®: Labcorp test 550510

Labcorp test 550510, CPT 87536. Specimen: Plasma, frozen. Turnaround: 17 - 25 days.

Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to PhenoSense GT® is Labcorp test code 550510, billed with CPT 87536. Specimen: Plasma, frozen. Turnaround time: 17 - 25 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code550510
CPT87536. If reflex testing is performed, concomitant CPT codes/charges will apply.
LOINC20447-9, 29541-0
SpecimenPlasma, frozen
Volume6 mL
Minimum volume4 mL ( Note: This volume does not allow for repeat testing.)
ContainerShip in two or more screw-cap polypropylene frozen transport tubes.
Turnaround time17 - 25 days
Storage / transportFreeze. Separate frozen sample required for PhenoSense GT® portion of the test. Frozen sample is preferred for the viral load assay but is also stable at room temperature for one day or refrigerated for five days. Freeze for long-term storage.

Also known as: HIV-1 Plasma Viremia; HIV-1 RNA by Real-time (RT) PCR, Quantitative; Reflex to PhenoSense GT®; Viral Load

Use

Detect and quantitate HIV-1 in plasma with reflex to PhenoSense GT® (at an additional charge) if viral load is >500 copies/mL.

Methodology

Cobas® AmpliPrep/Cobas® TaqMan® HIV-1 Test, Version 2.0

Collection instructions

Collect specimen in three lavender-top (EDTA) tubes or three PPT™ tubes. Do not use green-top (heparin) tubes. Centrifuge specimen within six hours of collection. Remove plasma, transfer plasma to screw-cap polypropylene transport tubes (not "pop-top" or "snap-cap"), and freeze. Ship frozen (preferred). Do not ship frozen in PPT™. If PPT™ is used to collect plasma, specimen must be transferred to screw-cap tubes prior to freezing to avoid false elevation of low viral load samples. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested .

Causes for rejection

Hemolysis; green-top (heparin) tube; specimen received in "pop-top" or "snap-cap" tube; quantity not sufficient for analysis; frozen PPT™

Limitations

Assay range: 20−10,000,000 copies/mL

LOINC map

Result codeResult nameUnitsResult LOINC
550445HIV-1 RNA by PCRcopies/mL20447-9
550446log10 HIV-1 RNAlog10copy/mL29541-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87536

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation