Human Immunodeficiency Virus 1 (HIV-1) RNA, Quantitative PCR, Plasma: Cleveland Clinic Laboratories test HIVRNA
Cleveland Clinic Laboratories test HIVRNA, CPT 87536. Specimen: Plasma. Turnaround: 1 - 3 days.
Also known as: HIV RNA; HIV RNA; HIVRNA; SQHIVRNA; viral load; AIDS
Test includes
HIV-1 RNA; HIV-1 RNA (copies/mL); HIV-1 RNA (log copies/mL)
Methodology
Polymerase Chain Reaction (PCR), Quant
Stability
| Temperature | Period |
|---|---|
| Ambient | 24 hours for plasma or for whole blood unspun/unseparated |
| Refrigerated | 6 days for plasma separated from whole blood within 24 hours; |
| 24 hours for whole blood unspun/unseparated | Frozen |
Special instructions
Collect EDTA plasma according to standard protocol. Separate plasma by centrifugation (at 1,100 RCF for a minimum of 10 minutes) within 24 hours of collection. Plasma must be aliquoted first if sample is to be frozen. Sample cannot be shared with a test performed outside of Molecular Microbiology. Sample can only be shared with HSVPCR, VZVPCR, CMVQNT, HCQPCR, HIVRNA, HBVDNU, EBVQNT, or BKQUAN.
Performed
7 days a week
Alternate specimens
2 mL; Plasma; EDTA (Lavender); Centrifuge, aliquot and refrigerate ASAP.; Collect EDTA plasma according to standard protocol. Centrifuge (at 1,300 RCF for a minimum of 10 minutes) and aliquot into a sterile secondary tube within 24 hours of collection. Plasma must be aliquoted first if sample is to be frozen. Sample cannot be shared with a test performed outside of Molecular Microbiology. Sample can only be shared with HSVPCR, VZVPCR, CMVQNT, HCQPCR, HIVRNA, HBVDNU, EBVQNT, or BKQUAN. 2 mL; Plasma; Pink KEDTA; Centrifuge and refrigerate.; Collect EDTA plasma according to standard protocol. Centrifuge (at 1,300 RCF for a minimum of 10 minutes) and aliquot into a sterile secondary tube within 24 hours of collection. Plasma must be aliquoted first if sample is to be frozen. Sample cannot be shared with a test performed outside of Molecular Microbiology. Sample can only be shared with HSVPCR, VZVPCR, CMVQNT, HCQPCR, HIVRNA, HBVDNU, EBVQNT, or BKQUAN.
Performing Laboratory
Cleveland Clinic Laboratories
View this test on Cleveland Clinic Laboratories's website → · Last checked 2026-11-29
Other tests billed with CPT 87536
- HIV-1 RNA by PCR, Quantitative
- Human Immunodeficiency Virus 1 (HIV-1) by Quantitative NAAT with Reflex to HIV-1 Drug Resistance by Next Generation Sequencing
- Human Immunodeficiency Virus 1 (HIV-1) by Quantitative NAAT, CSF
- Human Immunodeficiency Virus 1 (HIV-1) by Quantitative NAAT, Plasma
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical)
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to HIV-1 GenoSure PRIme®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to HIV-1 GenoSure PRIme® or GenoSure Archive®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to HIV-1 GenoSure® MG
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to HIV-1 PhenoSense GT® Plus Integrase
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to PhenoSense Entry®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to PhenoSense GT®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to PhenoSense Integrase®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to PhenoSense®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) With Reflex to Trofile®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical)
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to HIV-1 GenoSure PRIme®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to HIV-1 GenoSure PRIme® or GenoSure Archive®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to HIV-1 GenoSure® MG
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to HIV-1 PhenoSense GT® Plus Integrase
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to PhenoSense Entry®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to PhenoSense GT®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to PhenoSense Integrase®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to PhenoSense®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Nongraphical) With Reflex to Trofile®
- Human Immunodeficiency Virus 1 (HIV-1), Quantitative, RNA (Abbott® RealTime)
Search the National Lab Test Directory · All Cleveland Clinic Laboratories tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation