Sound Lab Consultants › National Lab Test Directory › Labcorp › Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical)

Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical): Labcorp test 550420

Labcorp test 550420, CPT 87536. Specimen: Plasma. Turnaround: 3 - 5 days.

Human Immunodeficiency Virus 1 (HIV-1), Quantitative, Real-time PCR (Graphical) is Labcorp test code 550420, billed with CPT 87536. Specimen: Plasma. Turnaround time: 3 - 5 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code550420
CPT87536
LOINC20447-9, 29541-0, 80563-0
SpecimenPlasma
Volume3.5 mL
Minimum volume1.1 mL ( Note: This volume does not allow for repeat testing.)
ContainerLavender-top (EDTA) tube or plasma preparation tube (PPT™)
Turnaround time3 - 5 days
Storage / transportFreeze (preferred) or refrigerate. Stable at room temperature for 24 hours or refrigerated for six days. Stable frozen for six weeks.

Also known as: HIV-1 Plasma Viremia; HIV-1 RNA by Real-time PCR, Quantitative

Use

This test is used to detect and quantitate HIV-1 in plasma.

Methodology

Cobas® HIV

Collection instructions

Centrifuge sample within 24 hours of collection. Transfer plasma to a screw-cap polypropylene transport tube. Ship frozen (preferred). To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit a separate frozen specimen for each test requested.

Causes for rejection

Incorrect anticoagulant; PPT™ frozen and/or not centrifuged

Special instructions

Submit the patient's Social Security number for serial monitoring. To order this test without the serial monitor service, use test 550430 .

Limitations

Assay range: 20−10,000,000 copies/mL Due to the potential cross-reactivity between some NAT assays and certain lentiviral vector-based CAR-T cell therapies, clinicians should exercise caution when ordering and interpreting HIV testing in patients who have received CAR-T cell therapy. Some lentiviral CAR-T vectors contain a target region of the test, which can lead to false positive HIV-1 results.

LOINC map

Result codeResult nameUnitsResult LOINC
550413HIV-1 RNA by PCRcopies/mL20447-9
550414log10 HIV-1 RNAlog10copy/mL29541-0
511958PDF80563-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87536

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation