Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Growth Hormone Binding Protein

Growth Hormone Binding Protein: Labcorp test 504591

Labcorp test 504591, CPT 83520. Specimen: Serum. Turnaround: 7 - 10 days.

Growth Hormone Binding Protein is Labcorp test code 504591, billed with CPT 83520. Specimen: Serum. Turnaround time: 7 - 10 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Quest Diagnostics, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code504591
CPT83520
LOINC—
SpecimenSerum
Volume0.3 mL
Minimum volume0.1 mL ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube; red-top tube
Turnaround time7 - 10 days
Storage / transportRefrigerate

Use

Reduced or absent GHBP is found in GH insensitivity due to inactivating receptor binding mutations as typified by Laron dwarfism. The most clinically relevant use of GHBP measurements is to confirm suspected Laron dwarf GH insensitivity due to genetic GH receptor defect. Other forms of GH receptor insensitivity, however may have normal or high GHBP levels. The levels of GHBP may be explained by the underlying mechanism for insensitivity, accordingly, inability to dimerize, errors in the trans-membrane structure, or in downstream actions may have high or normal GHBP levels. Studies show that GHBP levels decrease in acromegaly, with normalization on successful treatment. The converse is not…

Methodology

Enzyme-linked immunosorbent assay (ELISA)

Collection instructions

Allow a minimum clotting time of 30 to 60 minutes with serum separation within 2 hours of collection. Send serum in a plastic transport tube.

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x6

Limitations

Results of this test are labeled for research purposes only by the assay's manufacturer. The performance characteristics of this assay have not been established by the manufacturer. The result should not be used for treatment or for diagnostic purposes without confirmation of the diagnosis by another medically established diagnostic product or procedure. The performance characteristics were determined by LabCorp.

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83520

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.