Adalimumab Level and Anti-Drug Antibody: Quest Diagnostics test 36296
Quest Diagnostics test 36296, CPT 80145, 83520. Specimen: 0.8 mL serum.
Adalimumab Level and Anti-Drug Antibody is Quest Diagnostics test code 36296, billed with CPT 80145, 83520. Specimen: 0.8 mL serum. Performing laboratory: Quest Diagnostics, CLIA
49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories, Cleveland Clinic Laboratories.
Test code36296
CPT83520, 80145
LOINC—
Specimen0.8 mL serum
Minimum volume0.5 mL
ContainerTransport tube
Storage / transportRefrigerated (cold packs)
Also known as: TNF inhibitor antibody; Anti-TNF inhibitor antibody; Anti-adalimumab antibody; Anti-Humira® anti-drug antibody; Anti-Humira® antibody; Humira® anti-drug antibody
Methodology
Chemiluminescent Immunoassay
Collection instructions
Draw blood in non-separator gel tube (red-top) or separator gel tube (SST). Centrifuge and transfer serum to a labeled plastic transport tube.
Stability
| Temperature | Period |
|---|
| Room temperature | 48 hours |
| Refrigerated | 8 days |
| Frozen | 28 days |
Patient preparation
Dietary supplements containing biotin may interfere in assays and may skew results to be either falsely high or falsely low. For patients receiving the recommended daily doses of biotin, draw samples at least 8 hours following the last biotin supplementation. For patients on mega-doses of biotin supplements, draw samples at least 72 hours following the last biotin supplementation.
Collect immediately before next scheduled dose (trough specimen).
Causes for rejection
Moderate and gross hemolysis
Assay category
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.
View this test on Quest Diagnostics's website → · Last checked 2026-11-29
Other tests billed with CPT 80145, 83520
- Adalimumab and Anti-Adalimumab Antibody, DoseASSURE™ ADL
LabcorpTest code 503890CPT 80145, 82397SerumTAT 6 - 10 days
- Adalimumab and Antibodies to Adalimumab Quantitation
ARUP LaboratoriesTest code 3017043CPT 80145, 82397Serum separator tube.TAT 3-7 days
- Adalimumab Level
Quest DiagnosticsTest code 36298CPT 801450.5 mL serum
- Adalimumab, Serum
Cleveland Clinic LaboratoriesTest code ADALIMCPT 80145, 83529SerumTAT 1 - 4 days
- 14-3-3 eta Protein by ELISA, Serum
ARUP LaboratoriesTest code 3017890CPT 83520Serum separator tube or red top tube.TAT 1-8 days
- 14.3.3 eta Protein, Serum
Cleveland Clinic LaboratoriesTest code 1433PCPT 83520SerumTAT 7 - 13 days
- 14.3.3 eta, Rheumatoid Arthritis
LabcorpTest code 504550CPT 83520Serum, frozenTAT 6 - 12 days
- Adalimumab Anti-Drug Antibody
Quest DiagnosticsTest code 36294CPT 835200.6 mL serum
- ADAMTS13 Antibody
LabcorpTest code 117915CPT 83520Plasma, frozenTAT 3 - 9 days
- ADAMTS13 Antibody
ARUP LaboratoriesTest code 3000182CPT 83520Light Blue (Sodium Citrate). Refer to Specimen Handling at aruplab.com for hemosTAT 1-8 days
- ADAMTS13 Reflex Panel
ARUP LaboratoriesTest code 3000239CPT 83520, 85335, 85397Light blue (sodium citrate). Refer to Specimen Handling at aruplab.com for hemosTAT 1-3 days
- Adiponectin
Cleveland Clinic LaboratoriesTest code ADIPCPT 83520SerumTAT 2 - 9 days
- Adiponectin
LabcorpTest code 004650CPT 83520Serum or plasmaTAT 7 - 8 days
- Adiponectin
Quest DiagnosticsTest code 15060CPT 835201 mL serum
- Adiponectin, Quantitative Serum/Plasma
ARUP LaboratoriesTest code 3017195CPT 83520Serum separator tube (SST), light green (lithium heparin with gel separator), orTAT 1-8 days
- Allergen, Hymenoptera Venoms With Components
ARUP LaboratoriesTest code 3020335CPT 83520, 86003, 86008Serum separator tube.TAT 1-4 days
- Alpha Subunit, Free, Pituitary Glycoprotein Hormones (PGH)
ARUP LaboratoriesTest code 2013034CPT 83520Serum separator tube (SST) or plain red.TAT 6-13 days
- Anti-Mutated Citrullinated Vimentin (MCV) Antibody, Serum
ARUP LaboratoriesTest code 3019462CPT 83520Serum separator tube (SST).TAT 1-8 days
- Anti-Myelin Associated Glycoprotein (MAG) IgM
LabcorpTest code 140120CPT 83520Serum, frozenTAT 4 - 7 days
- CAR Autoantibody
Cleveland Clinic LaboratoriesTest code CARABCPT 83520SerumTAT 4 - 6 days
- Coagulation Activation Profile
LabcorpTest code 117410CPT 83520, 85379Plasma, frozenTAT 5 - 8 days
- Collagen Binding Assay
Cleveland Clinic LaboratoriesTest code CBACPT 83520PlasmaTAT 1 - 3 days
- Collagen Type II Antibody
Cleveland Clinic LaboratoriesTest code CIIABCPT 83520SerumTAT 5 - 19 days
- Collagen Type II Antibody by ELISA, Serum
ARUP LaboratoriesTest code 2011056CPT 83520Plain red or serum separator tube (SST).TAT 8-18 days
- Complete Atopic Dermatitis Panel
Cleveland Clinic LaboratoriesTest code ATOPICCPT 82785, 83520, 86003SerumTAT 6 - 8 days
- Cytokine Panel 13, CSF
ARUP LaboratoriesTest code 3003259CPT 83520, 83529CSF.TAT 1-4 days
- Cytokine Panel 13, Plasma
ARUP LaboratoriesTest code 3002601CPT 83520, 83529Green (lithium heparin).TAT 1-4 days
- Cytokine Panel 13, Serum
ARUP LaboratoriesTest code 0051394CPT 83520, 83529Serum separator tube, or plain red.TAT 1-4 days
- Cytokine Panel, Monokines, Plasma
ARUP LaboratoriesTest code 3002616CPT 83520, 83529Green (lithium heparin).TAT 1-4 days
- Cytokine Panel, Monokines, Serum
ARUP LaboratoriesTest code 0051524CPT 83520, 83529Serum separator tube, or plain red.TAT 1-4 days
Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.