Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Anti-Myelin Associated Glycoprotein (MAG) IgM

Anti-Myelin Associated Glycoprotein (MAG) IgM: Labcorp test 140120

Labcorp test 140120, CPT 83520. Specimen: Serum, frozen. Turnaround: 4 - 7 days.

Anti-Myelin Associated Glycoprotein (MAG) IgM is Labcorp test code 140120, billed with CPT 83520. Specimen: Serum, frozen. Turnaround time: 4 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Quest Diagnostics.
LaboratoryLabcorp
CLIA number34D0655059
Test code140120
CPT83520
LOINC21411-4
SpecimenSerum, frozen
Volume0.3 mL
Minimum volume0.1 mL ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube or red-top tube
Turnaround time4 - 7 days
Storage / transportFreeze

Use

The BUHLMANN Anti-MAG™ ELISA is intended for the quantitative in vitro diagnostic determination of human IgM autoantibodies directed against Myelin Associated Glycoprotein (MAG).

Methodology

BUHLMANN™ anti-MAG ELISA. This assay measures antibodies to purified human MAG and has been employed in numerous clinical studies.

Collection instructions

Separate serum from cells. Transfer the serum into a LabCorp PP transpak frozen purple tube with screw cap (LabCorp No. 49482). Freeze immediately and maintain frozen at ≤ -20°C until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.

Stability

TemperaturePeriod
Frozen1 year (stability determined by manufacturer or literature reference)
Freeze/thaw cyclesStable x2 (stability determined by manufacturer or literature reference)

Patient preparation

Lipemic samples can be avoided by having the patient fast for 12 hours prior to collection.

Causes for rejection

Non-serum sample received; non-frozen serum received; grossly lipemic, hemolytic or icteric sample received; cryoglobulin present

Reference range

0-999 BTU

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
140121MAG IgM AutoantibodiesBTU21411-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83520

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation