Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Plasminogen Act Inhibitor-1,Ag

Plasminogen Act Inhibitor-1,Ag: Labcorp test 146790

Labcorp test 146790, CPT 85415. Specimen: Plasma, frozen. Turnaround: 4 - 7 days.

Plasminogen Act Inhibitor-1,Ag is Labcorp test code 146790, billed with CPT 85415. Specimen: Plasma, frozen. Turnaround time: 4 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code146790
CPT85415
LOINC22758-7
SpecimenPlasma, frozen
Volume1.0 mL
Minimum volume0.5 mL ( Note: This volume does not allow for repeat testing.)
ContainerBlue-top (sodium citrate) tube
Turnaround time4 - 7 days
Storage / transportFreeze.

Also known as: PAI; PAI-1; PAI1; Plasminogen Activator Inhibitor-1, Antigen

Use

Plasminogen activator inhibitor-1 (PAI-1) is a member of a family of proteins that inhibit plasminogen activators. PAI-1 is a single-chain glycoprotein with a molecular weight of 47 kilodaltons. During fibrinolysis, tissue plasminogen activator (tPA) converts the inactive protein plasminogen into plasmin. Plasmin, in turn, plays a critical role in fibrinolysis by degrading fibrin and also provides localized protease activity in a number of physiological functions, including ovulation, cell migration, and epithelial cell differentiation. PAI-1 is the primary inhibitor of tPA and other plasminogen activators in the blood. PAI-1 limits the production of plasmin and serves to keep fibrinolysis…

Methodology

Enzyme-linked immunosorbent assay (ELISA)

Collection instructions

Citrated plasma samples should be collected by double centrifugation. Platelet-poor plasma is needed. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a LabCorp PP transpak frozen purple tube with screw cap (LabCorp No. 49482). Freeze immediately and maintain frozen until tested. Print and use the Specimen Collection Bulletin as a tube-filling guide.

Causes for rejection

Non-citrate plasma received; sample received unfrozen

Special instructions

If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.

Limitations

Samples containing platelets prior to freezing will give erroneously high results due to the release of latent PAI-1 from platelet granules. PAI-1 is an acute phase reactant and can become transiently elevated by infection, inflammation and trauma. PAI-1 levels increase during pregnancy. Since the PAI-1 antigen assay measures both functional and dysfunctional protein, it is of limited utility in the assessment of congenital PAI-1 deficiency.

LOINC map

Result codeResult nameUnitsResult LOINC
146791Plasminogen Act Inhibitor-1,Agng/mL22758-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85415

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.