Tissue Plasminogen Activator (tPA) Antigen: Labcorp test 146010
Labcorp test 146010, CPT 85415. Specimen: Plasma, frozen. Turnaround: 5 - 8 days.
Use
This test is used for quantitative determination of human tissue plasminogen activator antigen in plasma by enzyme immunoassay.
Methodology
Enzyme-linked immunosorbent assay (ELISA)
Collection instructions
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set, a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Double centrifugation is required for this test to ensure the removal of platelets that contain fibrinolysis factors. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and re-centrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Causes for rejection
Hemolysis; specimen clotted with fibrin; specimen contaminated with heparin (i.e., drawn with blood gases)
Reference range
0.0–12.0 ng/mL
Limitations
As with all test containing monoclonal mouse antibodies, erroneous findings may be obtained from samples taken from patients who have been treated with monoclonal mouse antibodies or who have received them for diagnostic purposes.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 146011 | Tissue Plasminogen Activator | ng/mL | 5971-7 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85415
- Bleeding With Normal aPTT/PT
- Fibrinolysis Profile
- Plasminogen Act Inhibitor-1,Ag
- Plasminogen Activator Inhibitor 1 (PAI-1) Activity
- Plasminogen Activator Inhibitor 1, Activity
- Plasminogen Activator Inhibitor Antigen
- Plasminogen Activator Inhibitor Antigen, Plasma
- Plasminogen Activator Inhibitor, Activity
- Thrombotic Risk, Congenital (Extended)
- Tissue Plasminogen Activator, Antigen
- Tissue Plasminogen Activator (TPA) Antigen
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation