Plasminogen Activator Inhibitor 1 (PAI-1) Activity: Labcorp test 146787
Labcorp test 146787, CPT 85415. Specimen: Plasma, frozen. Turnaround: 3 - 5 days.
Also known as: PAI-1
Methodology
Enzyme-linked immunosorbent assay (ELISA)
Collection instructions
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge and carefully remove the plasma using a plastic transfer pipette, being careful not to disturb the cells. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested . Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Stability
| Temperature | Period |
|---|---|
| Room temperature | Unstable |
| Refrigerated | Unstable |
| Frozen | 11 days |
Causes for rejection
Specimen received unfrozen; noncitrated plasma specimen
Special instructions
If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Sample Collection for Coagulation Testing for directions.
Limitations
PAI-1 is a acute-phase reactant and can become transiently elevated by infection, inflammation, or trauma. PAI-1 levels increase during pregnancy.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 146788 | Plasminogen Act Inhibitor-1 | IU/mL | 5975-8 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85415
- Bleeding With Normal aPTT/PT
- Fibrinolysis Profile
- Plasminogen Act Inhibitor-1,Ag
- Plasminogen Activator Inhibitor 1, Activity
- Plasminogen Activator Inhibitor Antigen
- Plasminogen Activator Inhibitor Antigen, Plasma
- Plasminogen Activator Inhibitor, Activity
- Thrombotic Risk, Congenital (Extended)
- Tissue Plasminogen Activator (tPA) Antigen
- Tissue Plasminogen Activator, Antigen
- Tissue Plasminogen Activator (TPA) Antigen
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation