Labcorp test 146704, CPT 83520. Specimen: Serum, frozen. Turnaround: 3 - 12 days.

Pancreatic Polypeptide is Labcorp test code 146704, billed with CPT 83520. Specimen: Serum, frozen. Turnaround time: 3 - 12 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Quest Diagnostics, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code146704
CPT83520
LOINC2721-9
SpecimenSerum, frozen
Volume0.5 mL
Minimum volume0.3 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time3 - 12 days
Storage / transportFreeze within four hours of collection.

Use

This test is used to measure pancreatic polypeptide in serum.

Methodology

Enzyme-linked immunosorbent assay (ELISA)

Collection instructions

Transfer the serum into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.

Stability

TemperaturePeriod
Room temperature4 hours
Refrigerated4 hours
Frozen14 days
Freeze/thaw cyclesStable x3

Patient preparation

Patients should fast for 10 hours prior to specimen collection. No radioisotopes should be administered during the 24 hours prior to specimen collection.

Causes for rejection

Specimen not frozen; specimen not serum

Reference range

0.0–378.9 pg/mL

Special instructions

Values obtained with different assay methods should not be used interchangeably in serial testing. It is recommended that only one assay method be used consistently to monitor each patient's course of therapy. This procedure does not provide serial monitoring; it is intended for one-time use only. If serial monitoring is required, please use the serial monitoring number 480704 to order.

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration. Elevated results can occur 30 to 90 minutes after a meal and after exercise. Can be elevated in patients with uncontrolled diabetes mellitus. Decreased results can be seen in patients treated with atropine or somatostatin.Can be decreased in patients with hyperglycemia, chronic pancreatitis or pancreatic resection, diarrhea, laxative abuse, GI inflammatory processes and chronic renal disease.

LOINC map

Result codeResult nameUnitsResult LOINC
146706Pancreatic Polypeptidepg/mL2721-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83520

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation