Interleukin-2 Soluble Receptor α: Labcorp test 142455

Labcorp test 142455, CPT 83520. Specimen: Serum, frozen. Turnaround: 3 - 6 days.

Interleukin-2 Soluble Receptor α is Labcorp test code 142455, billed with CPT 83520. Specimen: Serum, frozen. Turnaround time: 3 - 6 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Quest Diagnostics, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code142455
CPT83520
LOINC44422-4
SpecimenSerum, frozen
Volume0.5 mL
Minimum volume0.3 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time3 - 6 days
Storage / transportFreeze.

Also known as: IL-2 sRα

Use

This test is used for the measurement of Interleukin-2 Soluble Receptor α (sIL-2Rα) levels in serum.

Methodology

Immunochemiluminometric assay (ICMA)

Collection instructions

Transfer the serum into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen specimens, please submit frozen specimens for each test requested .

Stability

TemperaturePeriod
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Thawed specimen

Reference range

223−710 units/mL

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration. sIL-2Rα level is only one out of eight criteria of which five have to be met to make a diagnosis. The combination of these clinical and laboratory criteria should warrant sufficient specificity. In order to reach a high specificity close to 100%, levels >10,000 U/mL are required. The clinical presentation of HLH can have considerable overlap with other inflammatory conditions. A normal or only modestly elevated sIL-2Rα, despite extremely elevated ferritin, suggests disseminated infection in the context of primary immunodeficiencies,…

LOINC map

Result codeResult nameUnitsResult LOINC
142457IL-2 Receptor AlphaU/mL44422-4

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83520

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation