Labcorp test 141531, CPT 86341. Specimen: Serum, frozen. Turnaround: 5 - 10 days.

IA2 Autoantibodies (Endocrine Sciences) is Labcorp test code 141531, billed with CPT 86341. Specimen: Serum, frozen. Turnaround time: 5 - 10 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Quest Diagnostics.
LaboratoryLabcorp
CLIA number34D0655059
Test code141531
CPT86341
LOINC31209-0
SpecimenSerum, frozen
Volume1 mL
Minimum volume0.5 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time5 - 10 days
Storage / transportFreeze . Freeze Freeze .

Also known as: IA 2 Antibodies; ICA512 Autoantibodies; Tyrosine Phosphatase Autoantibodies

Methodology

Enzyme-linked Immunosorbent Assay (ELISA)

Collection instructions

Transfer the serum into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested. Transfer the serum into a Lab Corp PP transpak frozen purple tube with screw cap (LabCorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested. Transfer the serum into a Lab corp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x6
TemperaturePeriod
Room temperature3 days
Refrigerated3 days
Frozen107 days
Freeze/thaw cyclesStable x6
TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x6

LOINC map

Result codeResult nameUnitsResult LOINC
141533IA-2 AutoantibodiesU/mL31209-0

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 86341

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation