Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Cleveland Clinic Laboratories › Autoimmune Encephalopathy Evaluation, Serum

Autoimmune Encephalopathy Evaluation, Serum: Cleveland Clinic Laboratories test ENCSER

Cleveland Clinic Laboratories test ENCSER, CPT 0432U, 83516, 86255, 86341. Specimen: Serum. Turnaround: 11 - 14 days.

Autoimmune Encephalopathy Evaluation, Serum is Cleveland Clinic Laboratories test code ENCSER, billed with CPT 0432U, 83516, 86255, 86341. Specimen: Serum. Turnaround time: 11 - 14 days. Performing laboratory: Cleveland Clinic Laboratories, CLIA 36D0656094 (Cleveland, OH). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp.
LaboratoryCleveland Clinic Laboratories
CLIA number36D0656094
Test codeENCSER
CPT86341 - QTY (1); 86255 - QTY (24); 0432U - QTY (1); 83516 - QTY (1)
LOINC—
SpecimenSerum
Volume4 mL
Minimum volume2.5 mL
ContainerNo additive (Red)
Turnaround time11 - 14 days
Storage / transportRefrigerated

Test includes

AK5 Ab IFA, S; GABA-A-R Ab CBA, S; KLHL11-IgG CBA, S; Ma2 Ab ELISA, S; mGluR5 Ab IFA, S; DPPX Ab CBA, S; IgLON5 CBA, S; PDE10A Ab IFA, S; TRIM46 Ab IFA, S; Neurochondrin IFA, S; Septin-7 IFA, S; AMPA-R Ab CBA, S; Amphiphysin Ab, S; AGNA-1, S; ANNA-1, S; ANNA-2, S; ANNA-3, S; CASPR2-IgG, CBA, S; CRMP-5-IgG, S; GABA-B-R Ab CBA, S; GAD65 Ab Assay, S; LGI1-IgG CBA, S; mGIuR1 Ab IFA, S; NMDA-R Ab CBA, S; PCA-1, S; PCA-2, S; PCA-Tr, S; Encephalopathy Interpretation, S

Methodology

Cell Binding Assay (CBA); Radioimmunoassay (RIA); Immunofluorescence

Stability

TemperaturePeriod
Refrigerated28 days
Frozen28 days
Ambient72 hours

Special instructions

Draw 2 tubes to ensure adequate serum volume. Patient should have no general anesthetic or muscle-relaxant medications in the previous 24 hours. Specimen collection is recommended before initiation of immunosuppressant medication. This test should not be requested in patients who have recently received radioisotopes (refer to Special Information).

Performed

Sun - Sat

Alternate specimens

4 mL; Serum; SST (Gold); Refrigerated; Draw 2 tubes to ensure adequate serum volume. Patient should have no general anesthetic or muscle-relaxant medications in the previous 24 hours. Specimen collection is recommended before initiation of immunosuppressant medication. This test should not be requested in patients who have recently received radioisotopes (refer to Special Information).

Performing Laboratory

Mayo Clinic Dpt of Lab Med & Pathology

View this test on Cleveland Clinic Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 0432U, 83516, 86255

Search the National Lab Test Directory · All Cleveland Clinic Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation