Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Autoimmune Neurologic Disease Panel With Reflex, CSF

Autoimmune Neurologic Disease Panel With Reflex, CSF: ARUP Laboratories test 3018967

ARUP Laboratories test 3018967, CPT 83519, 84182, 86255, 86256, 86341. Specimen: CSF. Turnaround: 3-10 days.

Autoimmune Neurologic Disease Panel With Reflex, CSF is ARUP Laboratories test code 3018967, billed with CPT 83519, 84182, 86255, 86256, 86341. Specimen: CSF. Turnaround time: 3-10 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Quest Diagnostics, Labcorp, Cleveland Clinic Laboratories.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code3018967
CPT86255 x12; 83519; 86341; 84182 x3; if reflexed, add 84182 x4; 86255; 86256 per titer
LOINC103715-9, 107194-3, 14247-1, 42501-7, 53707-6, 57750-2, 68913-3, 80220-7
SpecimenCSF
Turnaround time3-10 days
Storage / transportFrozen

Also known as: AMPA; amphiphysin; ANNA; CASPR2; CRMP5; CV2; dementia; DNER; DPPX; dysautonomia; encephalitis; encephalopathy; epilepsy; GABA-A; GABA-B; GAD; GAD 65; GAD65; Hu; IgLON5; ITPR1; LGI1; mGluR1; movement disorders; myelopathy; NMDA; paraneoplastic; PCCA; Ri; Sox-1; Tr; VGKC; Yo

Use

Use to evaluate suspected autoimmune disease of the central nervous system. Targeted phenotype-specific panels are preferred for the evaluation of autoimmune neurologic disease. Refer to the Autoimmune Neurologic Disease Panel With Reflex, Serum and CSF Test Fact Sheet for phenotype-specific test options. Testing in both serum and CSF is recommended to maximize diagnostic yield; refer to Autoimmune Neurologic Disease Panel with Reflex, Serum ( 3018965 ) for serum testing.

Methodology

Semi-Quantitative Cell-Based Indirect Fluorescent Antibody / Qualitative Immunoblot / Quantitative Radioimmunoassay (RIA) / Semi-Quantitative Enzyme-Linked Immunosorbent Assay (ELISA) / Semi-Quantitative Indirect Fluorescent Antibody (IFA)

Collection instructions

Transfer 4 mL to ARUP standard transport tube. (Min: 2 mL)

Stability

Ambient: 24 hours; Refrigerated: 1 week; Frozen: 1 month (Three freeze/thaw cycles are acceptable.)

Causes for rejection

Fluid other than CSF. Grossly hemolyzed specimens.

Reference range

Test Number Components Reference Interval KLHL11 Ab IgG CBA-IFA Screen, CSF Less than 1:1 Ma2/Ta Antibody, IgG by Immunoblot, CSF Negative mGluR1 Ab IgG CBA-IFA Screen, CSF Less than 1:1 IgLON5 Ab IgG CBA-IFA Screen, CSF Less than 1:1 GABA-AR Ab IgG CBA-IFA Screen, CSF Less than 1:1 DPPX Ab IgG CBA-IFA Screen, CSF Less than 1:1 Amphiphysin Antibody, CSF Negative SOX1 Antibody, IgG by Immunoblot, CSF Negative Glutamic Acid Decarboxylase Antibody CSF 0.0-5.0 IU/mL CV2 Ab IgG CBA-IFA Screen, CSF Less than 1:1 LGI1 Ab IgG CBA-IFA Screen, CSF Less than 1:1 CASPR2 Ab IgG CBA-IFA Screen, CSF Less than 1:1 Voltage-Gated Potassium Channel Ab, CSF 1.1 pmol/L or less GABA-BR Ab IgG CBA-IFA Screen, CSF Less than 1:1 AMPA Receptor Ab IgG CBA-IFA Screen, CSF Less than 1:1 Paraneoplastic Abs (PCCA/ANNA) IgG, CSF None Detected NMDA Receptor Ab IgG CBA-IFA, CSF Less than 1:1

Performed

Tue

Compliance Category

Laboratory Developed Test (LDT)

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
2005165NMDA Receptor Ab IgG CBA-IFA, CSF80220-7
2010842Paraneoplastic Abs (PCCA/ANNA) IgG, CSF14247-1
3001258AMPA Receptor Ab IgG CBA-IFA Screen, CSF82732-9
3001268GABA-BR Ab IgG CBA-IFA Screen, CSF82984-6
3001388Voltage-Gated Potassium Channel Ab, CSF68913-3
3001987CASPR2 Ab IgG CBA-IFA Screen, CSF90820-2
3001991LGI1 Ab IgG CBA-IFA Screen, CSF90830-1
3002259CV2 Ab IgG CBA-IFA Screen, CSF53707-6
3002789Glutamic Acid Decarboxylase Antibody CSF42501-7
3002904SOX1 Antibody, IgG by Immunoblot, CSF94383-7
3004511Amphiphysin Antibody, CSF57750-2
3004513DPPX Ab IgG CBA-IFA Screen, CSF94283-9
3006004GABA-AR Ab IgG CBA-IFA Screen, CSF103715-9
3006014IgLON5 Ab IgG CBA-IFA Screen, CSF96481-7
3006040mGluR1 Ab IgG CBA-IFA Screen, CSF93500-7
3017504Ma2/Ta Antibody, IgG by Immunoblot, CSF107194-3
3018736KLHL11 Ab IgG CBA-IFA Screen, CSF99073-9

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 83519, 84182, 86255

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation