Human Antimouse Antibodies: Labcorp test 140657

Labcorp test 140657, CPT 83520. Specimen: Serum. Turnaround: 6 - 10 days.

Human Antimouse Antibodies is Labcorp test code 140657, billed with CPT 83520. Specimen: Serum. Turnaround time: 6 - 10 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Quest Diagnostics, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code140657
CPT83520
LOINC14975-7
SpecimenSerum
Volume0.4 mL
Minimum volume0.2 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time6 - 10 days
Storage / transportFreeze.

Also known as: HAMA

Use

This test is intended for the detection and semi-quantitation of human antibodies to mouse IgG (HAMA).

Methodology

Enzyme-linked immunosorbent assay (ELISA). The ImmuSTRIP® HAMA ELISA Test System employs a control mouse polyclonal antibody as the capture antibody and a mouse anti-isotypic monoclonal IgG1 to detect HAMA. The test has been calibrated with baboon anti-mouse IgG serum. Final patient values are reported as nanograms of precipitable antibody present in the sample per mL.

Collection instructions

Once the serum has been separated from the clot, it may be stored at 2-8ºC for up to 24 hours. If the serum specimen cannot be tested within one day of collection, the specimen should be stored at -70ºC until tested. Serum samples are stable at -70ºC for at least three months. Freeze and thaw only once.

Stability

TemperaturePeriod
Room temperatureNot established (stability provided by manufacturer or literature reference)
Refrigerated24 hours (stability provided by manufacturer or literature reference)
Frozen3 months (stability provided by manufacturer or literature reference)
Freeze/thaw cyclesStable x1 (stability provided by manufacturer or literature reference)

Causes for rejection

Nonserum specimen; gross lipemia

Reference range

0−74 ng/mL

Limitations

The presence of Rheumatoid Factor (RF) and/or heterophilic antibodies in the sample may interfere with the assay and could result in false-positive values. Lipemic serum samples may interfere with the assay and could result in false-positive values.

LOINC map

Result codeResult nameUnitsResult LOINC
140684Human Anti-mouse Antibodiesng/mL14975-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83520

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation