Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Partial Thromboplastin Time (PTT), Activated

Partial Thromboplastin Time (PTT), Activated (Spe): Labcorp test 005207

Labcorp test 005207, CPT 85730. Specimen: Whole blood or plasma. Turnaround: Within 1 day.

Partial Thromboplastin Time (PTT), Activated is Labcorp test code 005207, billed with CPT 85730. Specimen: Whole blood or plasma. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code005207 (Spe)
CPT85730
LOINC14979-9
SpecimenWhole blood or plasma
Volume4.5 mL, 2.7 mL, 1.8 mL
Minimum volume90% of full draw ( Note: This volume does not allow for repeat testing.)
ContainerBlue-top (sodium citrate) tube
Turnaround timeWithin 1 day
Storage / transportSpecimens are stable at room temperature for 24 hours. If testing cannot be completed within 24 hours, specimens should be centrifuged for at least 10 minutes at 1500xg. Plasma should then be transferred to a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Refer to Coagulation Collection Procedures for directions. Requirements for patients receiving heparin are different: If testing cannot be performed within one hour of collection, frozen plasma must be submitted. Specimens should be centrifuged for at least 15 minutes at 1500xg to produce platelet-poor plasma and the plasma quick frozen and maintained in this condition until tested.

Also known as: Activated Partial Thromboplastin Time (aPTT)

Use

The aPTT is sensitive to deficiency or inhibition of factors in the intrinsic pathway. These include the contact factors; high molecular weight kininogen (HMWK), prekallikrein, and factor XII along with procoagulant factors XI, IX, VIII. The aPTT is less sensitive to deficiencies of X, V, prothrombin, and fibrinogen. Nonspecific, lupus-type anticoagulants can also extend the aPTT, but the more sensitive aPTT-LA test should be used to screen for this condition.

Methodology

The aPTT reagent consisting of silica mixed with synthetic phospholipid is mixed with the patient plasma. The silica provides a negatively-charged particulate surface for the activation of the contact pathway of coagulation. Calcium chloride is then added to the sample/reagent mixture to initiate clot formation. The time to clot formation is measured photo-optically.

Collection instructions

Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.

Patient preparation

Draw specimen one hour before next dose of heparin if heparin is being given by intermittent injection. Do not draw from an arm with a heparin lock or heparinized catheter.

Causes for rejection

Gross hemolysis; clotted specimen; frozen specimen thawed in transit; tubes <90% full; improper labeling; specimen collected in tube other than 3.2% citrate; refrigerated sample

Reference range

See table. Activated Partial Thromboplastin Time (aPTT) Age Range 1 d 29–38 sec 3 d 25−36 sec 1 to 11 m 30−39 sec 1 to 5 y 29−37 sec 6 to 10 y 27–37 sec 11 to 16 y 25–34 sec >16 y 23–34 sec

Special instructions

This test is for screening purposes only; it should not be used for therapeutic unfractionated heparin monitoring. Please refer to test Heparin Anti-Xa [117101] . If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.

Limitations

The aPTT-LA is a more sensitive screening test for identifying lupus anticoagulants in patients with a history of thrombosis. The aPTT may not be extended in individual factor deficiencies unless the levels drop below 15% to 45% depending on the factor. Less significant individual factor deficiencies in combination (multiple factor deficiency) can extend the aPTT. The aPTT is more sensitive to intrinsic pathway factor deficiencies than common pathway factor deficiencies. Factor VIII elevations, as can occur due to acute phase reactions, can normalize a mildly extended aPTT result. A large number of conditions can complicate the use of the aPTT in monitoring UFH therapy, The College of…

LOINC map

Result codeResult nameUnitsResult LOINC
015116aPTTsec14979-9

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 85730

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation