Prothrombin Fragment 1+2: Labcorp test 117230
Labcorp test 117230, CPT 83520. Specimen: Plasma, frozen. Turnaround: 5 - 9 days.
Use
This test is used for evaluation of F 1+2 in plasma as a determinant of in vivo thrombin generation.
Methodology
Prothrombin fragment 1+2 (F1+2) is measured by an enzyme immunoassay based on the sandwich principle. F 1+2 in the sample binds to anti-F 1+2 antibodies fixed to the microtiter plate during an incubation period. Peroxidase conjugated antibodies are then added and a second incubation takes place. A chromophore is added and color formation is directly proportional to the concentration of F 1+2.
Collection instructions
Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood-to-anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples unless the sample is collected using a winged (butterfly) collection system. With a winged blood collection set, a discard tube should be drawn first to account for the dead space of the tubing and prevent under-filling of the evacuated tube. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternative anticoagulant should be collected after the blue-top tube. Double centrifugation is required for this test to ensure the removal of platelets that contain fibrinolysis factors. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove 2/3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and re-centrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Patient preparation
Do not draw from an arm with a heparin lock or heparinized catheter.
Causes for rejection
Gross hemolysis; clotted specimen; frozen specimen thawed in transit; improper labeling; improper collection tube
Reference range
69–229 pmol/L
Limitations
Improper collection of the sample or insufficient mixing of the sample and anticoagulant in the collection tube can lead to falsely elevated F1+2 values. As with all tests containing monoclonal mouse antibodies, erroneous findings may be obtained from samples taken from patients who have been treated with monoclonal mouse antibodies or who have received them for diagnostic purposes.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 117231 | Prothrombin Fragment 1+2 | pmol/L | 25742-8 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 83520
- 14-3-3 eta Protein by ELISA, Serum
- 14.3.3 eta Protein, Serum
- 14.3.3 eta, Rheumatoid Arthritis
- Adalimumab Anti-Drug Antibody
- Adalimumab Level and Anti-Drug Antibody
- ADAMTS13 Antibody
- ADAMTS13 Antibody
- ADAMTS13 Reflex Panel
- Adiponectin
- Adiponectin
- Adiponectin
- Adiponectin
- Adiponectin, Quantitative Serum/Plasma
- aHUS (complement-mediated TMA) Panel
- Allergen, Hymenoptera Venoms With Components
- Alpha Subunit
- Alpha Subunit, Free, Pituitary Glycoprotein Hormones (PGH)
- ANA, IFA, Cascade and Rheumatoid Arthritis Panel 2, with Reflexes
- ANAlyzeR™ ANA, IFA with Reflex Titer/Pattern, Systemic Autoimmune Panel 1
- Angiotensin I, Plasma
- Anti-cN-1A Ab
- Anti-Mutated Citrullinated Vimentin (MCV) Antibody, Serum
- Anti-Myelin Associated Glycoprotein (MAG) IgM
- Anti-Phosphatidylethanolamine Panel
- Autoimmune Hepatitis Differential Panel for Hep-C Patient
- C1 Esterase Inhibitor, Functional
- C3 Glomerulopathy Complement Panel
- CAR Autoantibody
- Coagulation Activation Profile
- Collagen Binding Assay
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation