Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Testosterone Free, Profile II

Testosterone Free, Profile II: Labcorp test 070130

Labcorp test 070130, CPT 82040, 84270, 84403. Specimen: Serum. Turnaround: 4 - 6 days.

Testosterone Free, Profile II is Labcorp test code 070130, billed with CPT 82040, 84270, 84403. Specimen: Serum. Turnaround time: 4 - 6 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code070130
CPT82040; 84270; 84403
LOINC13967-5, 1751-7, 2986-8, 2991-8, 58952-3
SpecimenSerum
Volume2.8 mL
Minimum volume2 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time4 - 6 days
Storage / transportRoom temperature

Also known as: Free Testosterone by Vermeulen Equation; Free Testosterone, Calculated

Test includes

Albumin; free testosterone, calculated; sex hormone binding globulin; testosterone by LC-MS

Use

Free testosterone is the concentration of unbound testosterone in serum. The majority (approximately 60% to 90%) of serum total testosterone is associated with sex hormone binding globulin (SHBG); this fraction is tightly bound and biologically unavailable to its target tissues. The remaining bioavailable testosterone is mostly bound to albumin, with only a small fraction (approximately 0.5% to 2%) circulating in the free form. Free testosterone is the form of testosterone that can diffuse into the tissues and act on receptors and is considered the active fraction by many physicians. Free testosterone assessment is recommended as a primary or secondary measure of androgen activity in men…

Methodology

Albumin: Colorimetric Testosterone: Liquid chromatography/tandem mass spectrometry (LC/MS-MS) SHBG: Electrochemiluminescence immunoassay (ECLIA)

Collection instructions

Serum should be transferred from cells within one hour of collection and transferred to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated7 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

See individual test components.

Reference range

See table. Age Male (pg/mL) Female (pg/mL) 0 to 1 y Not established Not established 2 to 5 y 0.1−0.5 0.2−0.7 6 to 7 y 0.1−0.9 0.4−7.6 8 y 0.2−0.8 0.4−7.6 9 y 0.2−1.4 0.4−7.6 10 y 0.3−3.6 0.4−7.6 11 y 0.3−7.9 0.4−7.6 12 y 0.6−32.0 0.4−7.6 13 y 1.4−98.1 1.6−15.4 14 y 8.5−105.6 1.6−15.4 15 y 14.0−128.1 1.6−15.4 16 y 30.5−147.6 1.6−15.4 17 y 38.7−157.6 1.6−15.4 18 to 30 y 47.7−173.9 1.1−12.9 31 to 40 y 42.3–190.0 0.7–7.9 41 to 50 y 30.3–183.2 0.5–6.0 51 to 60 y 35.8–168.2 0.4–6.7 61 to 70 y 34.7–150.3 0.4–7.0 71 to 80 y 31.7–120.8 0.3–5.7 81 to 100 y 20.7–97.4 0.2–5.6

Special instructions

This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

See individual test components. This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration.

LOINC map

Result codeResult nameUnitsResult LOINC
001081Albuming/dL1751-7
070036Testosterone, Total, LC/MSng/dL2986-8
082016Sex Horm Binding Glob, Serumnmol/L13967-5
004230Testost., Free, Calcpg/mL2991-8

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82040, 84270, 84403

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation