Labcorp test 002238, CPT 82040, 82042, 82784. Specimen: Serum and cerebrospinal fluid (CSF). Turnaround: 3 - 6 days.

Immunoglobulin G Index is Labcorp test code 002238, billed with CPT 82040, 82042, 82784. Specimen: Serum and cerebrospinal fluid (CSF). Turnaround time: 3 - 6 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code002238
CPT82040; 82042; 82784(x2)
LOINC1746-7, 1751-7, 2464-6, 2465-3
SpecimenSerum and cerebrospinal fluid (CSF)
Volume1.5 mL serum and 1 mL CSF
Minimum volume0.7 mL serum and 0.5 mL CSF ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube and sterile (CSF) container
Turnaround time3 - 6 days
Storage / transportRoom temperature

Also known as: CSF IgG Index; CSF IgG:CSF Albumin Ratio; CSF IgG:CSF Total Protein Ratio; IgG Index, CSF; IgG Ratios and IgG Index, CSF

Test includes

IgG and albumin quantitation in both serum and spinal fluid; CSF IgG:CSF albumin ratio; CSF IgG index

Use

Detect and measure the level of IgG production by the central nervous system; has been applied to the diagnosis of multiple sclerosis along with CSF IgG synthesis rate and CSF immunoglobulin “oligoclonal” bands

Methodology

CSF IgG, CSF albumin, and serum IgG: immunologic; serum albumin: spectrophotometry; ratio and index by calculation

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen6 weeks
Freeze/thaw cyclesStable x2

Reference range

Index: 0.0−0.7

Special instructions

The third tube of a routinely obtained three-tube set of CSF should be used for these studies.

Limitations

Conditions in which lymphoreticular elements of the CNS produce immunoglobulins will result in false-positive (in relation to multiple sclerosis) elevations. Such conditions include, but are not limited to, aseptic meningitis, lymphoma, neurosyphilis, Guillain-Barré syndrome, and cerebral lupus erythematosus. These conditions, however, are either uncommon or are not frequently associated with an increased IgG index.

LOINC map

Result codeResult nameUnitsResult LOINC
IgG, Quant, CSFmg/dL2464-6
Albumin, CSFmg/dL1746-7
Immunoglobulin G, Qn, Serummg/dL2465-3
Albuming/dL1751-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 82040, 82042, 82784

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation