Oligoclonal Band Profile: ARUP Laboratories test 0080440

ARUP Laboratories test 0080440, CPT 82040, 82042, 82784, 83916. Specimen: CSF AND serum separator tube or plain red.. Turnaround: 1-3 days.

Oligoclonal Band Profile is ARUP Laboratories test code 0080440, billed with CPT 82040, 82042, 82784, 83916. Specimen: CSF AND serum separator tube or plain red.. Turnaround time: 1-3 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code0080440
CPT83916; 82784 x2; 82040; 82042
LOINC12782-9, 14116-8, 14117-6, 1746-7, 1751-7, 1756-6, 2464-6, 2465-3
SpecimenCSF AND serum separator tube or plain red.
Turnaround time1-3 days
Storage / transportRefrigerated.

Also known as: MS Panel; MS Profile; Multiple Sclerosis Panel without Myelin Basic Protein; Multiple Sclerosis Profile; Oligoclonal Banding; Multiple Sclerosis Panel; CSF Oligoclonal Bands

Use

Preferred test in the assessment of multiple sclerosis to detect unique IgG oligoclonal bands in cerebrospinal fluid (CSF) in conjunction with a matched serum specimen. Test calculates CSF IgG index.

Methodology

Qualitative Isoelectric Focusing/Electrophoresis/Quantitative Immunoturbidimetry

Collection instructions

Allow serum to clot completely at room temperature. Separate serum from cells ASAP or within 2 hours of collection. Transport two specimens. Transfer 1.5 mL CSF to an ARUP standard transport tube. (Min: 1.0 mL) AND transfer 1 mL serum to an ARUP standard transport tube. (Min: 0.6 mL)

Stability

Ambient: Unacceptable; Refrigerated: 2 weeks; Frozen: 6 months

Causes for rejection

Grossly bloody or hemolyzed specimens or severe lipemia.

Reference range

Test Number Components Reference Interval Albumin, CSF 0-35 mg/dL Immunoglobulin G Age Reference Interval (mg/dL) 0-2 years 242-1108 3-4 years 485-1160 5-9 years 514-1672 10-14 years 581-1652 15-18 years 479-1433 19 years and older 768-1632 Immunoglobulin G CSF 0.0-6.0 mg/dL Albumin, Serum 3500-5200 mg/dL Albumin Index 0.0-9.0 CSF IgG Synthesis Rate Less than or equal to 8.0 mg/d CSF IgG/Albumin Ratio 0.09-0.25 IgG Index 0.28-0.66 Oligoclonal Bands Number, CSF 0 - 1 Bands

Remarks

Recommendation is for CSF and serum to be collected within 24 hours of each other. Specimens collected outside this timeframe will be accepted at ordering provider's discretion.

Performed

Sun-Sat

Compliance Category

FDA

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
0050200Albumin, CSF1746-7
0050350Immunoglobulin G2465-3
0050670Immunoglobulin G CSF2464-6
0050671Albumin, Serum1751-7
0050672Albumin Index1756-6
0050675CSF IgG Synthesis Rate14116-8
0080095CSF Oligoclonal Bands12782-9
0080099Interpretation49293-4
0080175CSF IgG/Albumin Ratio2470-3
0080180IgG Index14117-6
2005461Oligoclonal Bands Number, CSF49852-7

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 82040, 82042, 82784

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation