Sound Lab Consultants › National Lab Test Directory › Labcorp › Sex Hormone-binding Globulin

Sex Hormone-binding Globulin: Labcorp test 082016

Labcorp test 082016, CPT 84270. Specimen: Serum. Turnaround: Within 1 day.

Sex Hormone-binding Globulin is Labcorp test code 082016, billed with CPT 84270. Specimen: Serum. Turnaround time: Within 1 day. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code082016
CPT84270
LOINC13967-5
SpecimenSerum
Volume1 mL
Minimum volume0.7 mL ( Note: This volume does not allow for repeat testing.)
ContainerGel-barrier tube (preferred) or red-top tube
Turnaround timeWithin 1 day
Storage / transportRoom temperature

Also known as: Testosterone-binding Globulin

Use

Levels of SHBG are under the positive control of estrogens and thyroid hormones and are suppressed by androgens. These influences dynamically control the liver synthesis of this carrier protein. Decreased levels of SHBG are frequently seen in hirsutism, virilization, obese postmenopausal women and in women with diffuse hair loss. Increased levels may be present in cases of hyperthyroidism, testicular feminization, cirrhosis, male hypogonadism, pregnancy, women using oral contraceptives and prepubertal children.

Methodology

Electrochemiluminescence immunoassay (ECLIA) This assay is performed on the Roche cobas instrument in multiple laboratories throughout Labcorp.

Collection instructions

If a red-top tube is used, transfer separated serum to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Citrate plasma specimen; EDTA plasma specimen; improper labeling

Reference range

• Male: − 20-49 years: 16.5−55.9 nmol/L − >49 years: 19.3−76.4 nmol/L • Female: − 20-49 years: 24.6−122.0 nmol/L − >49 years: 17.3−125.0 nmol/L

Special instructions

This test may exhibit interference when sample is collected from a person who is consuming a supplement with a high dose of biotin (also termed as vitamin B7 or B8, vitamin H, or coenzyme R). It is recommended to ask all patients who may be indicated for this test about biotin supplementation. Patients should be cautioned to stop biotin consumption at least 72 hours prior to the collection of a sample.

Limitations

As with all tests containing monoclonal mouse antibodies, erroneous findings may be obtained from samples taken from patients who have been treated with monoclonal mouse antibodies or who have received them for diagnostic purposes. In rare cases, interference due to extremely high titers of antibodies to streptavidin and ruthenium can occur. The test contains additives that minimize these effects.

LOINC map

Result codeResult nameUnitsResult LOINC
082016Sex Horm Binding Glob, Serumnmol/L13967-5

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 84270

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation