Labcorp test 004180, CPT 83520. Specimen: Serum. Turnaround: 4 - 7 days.

Eosinophil Cationic Protein (ECP) is Labcorp test code 004180, billed with CPT 83520. Specimen: Serum. Turnaround time: 4 - 7 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Quest Diagnostics, Michigan Medicine Laboratories (MLabs).
LaboratoryLabcorp
CLIA number34D0655059
Test code004180
CPT83520
LOINC25638-8
SpecimenSerum
Volume0.5 mL
Minimum volume0.3 mL ( Note: This volume does not allow for repeat testing.)
ContainerNMR lipoprofile serum-separator tube (No. 60360). Other tubes should not be used as they may produce erroneous results.
Turnaround time4 - 7 days
Storage / transportRefrigerate.

Also known as: Ribonuclease 3

Use

Measurement of the level of Eosinophil Cationic Protein (ECP) in serum

Methodology

ImmunoCAP®

Collection instructions

Allow the sample to stand for 60 to 120 minutes to release the ECP in the cells prior to centrifugation. Separate the serum after 60 to 120 minutes and transfer to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature5 days
Refrigerated14 days
Frozen14 days
Freeze/thaw cyclesStable x3

Causes for rejection

Nonserum sample received; non-Greiner tube collected; grossly hemolyzed or lipemic samples

Reference range

4−54 μg/L

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration. BD plastic serum-separator tubes should not be used as they will produce erroneous results. ECP has limited utility as a diagnostic marker of asthma because changes in serum ECP level have been registered in other atopic diseases like allergic rhinitis, but also in conditions not related to the eosinophil inflammation, such as bacterial sinusitis. Also, ECP application is limited only to the allergic type of asthma.

LOINC map

Result codeResult nameUnitsResult LOINC
004181ECPug/L25638-8

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83520

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation