Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Voltage-Gated Potassium Channel (VGKC) Complex Antibody Panel with Reflex to Titer, CSF

Voltage-Gated Potassium Channel (VGKC) Complex Antibody Panel with Reflex to Titer, CSF: ARUP Laboratories test 3001996

ARUP Laboratories test 3001996, CPT 83519, 86255, 86256. Specimen: CSF.. Turnaround: 1-8 days.

Voltage-Gated Potassium Channel (VGKC) Complex Antibody Panel with Reflex to Titer, CSF is ARUP Laboratories test code 3001996, billed with CPT 83519, 86255, 86256. Specimen: CSF.. Turnaround time: 1-8 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Quest Diagnostics, Michigan Medicine Laboratories (MLabs), Labcorp, Cleveland Clinic Laboratories.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code3001996
CPT83519; 86255 x2; if reflexed add 86256 per titer
LOINC68913-3, 90820-2, 90830-1
SpecimenCSF.
Turnaround time1-8 days
Storage / transportRefrigerated.

Use

Detect antibodies to voltage-gated potassium channel (VGKC) antibody receptor complex-associated, leucine-rich glioma inactivated 1 protein (LGI1) and contactin associated protein 2 (CASPR2). Antibodies are associated with acquired neuromyotonia, limbic encephalitis, painful neuropathy, Morvan syndrome, and rare tumors (eg, thymoma, small cell lung cancer). Serum is the preferred specimen type; see Voltage-Gated Potassium Channel (VGKC) Antibody with Reflex to LGI1 and CASPR2 Screen and Titer, Serum ( 2009463 ).

Methodology

Quantitative Radioimmunoassay/Semi-Quantitative Cell-Based Indirect Fluorescent Antibody

Collection instructions

Transfer 4 mL CSF to an ARUP Standard Transport Tube. (Min: 1.0 mL)

Stability

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 month

Causes for rejection

Plasma. Grossly lipemic or icteric specimens.

Reference range

Test Number Components Reference Interval Voltage-Gated Potassium Channel Ab, CSF 1.1 pmol/L or less LGI1 Ab IgG CBA-IFA Screen, CSF Less than 1:1 CASPR2 Ab IgG CBA-IFA Screen, CSF Less than 1:1

Performed

Wed

Compliance Category

Laboratory Developed Test (LDT)

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
3001388Voltage-Gated Potassium Channel Ab, CSF68913-3
3001987CASPR2 Ab IgG CBA-IFA Screen, CSF90820-2
3001991LGI1 Ab IgG CBA-IFA Screen, CSF90830-1

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 83519, 86255, 86256

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation