Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Ganglionic Acetylcholine Receptor Autoantibody

Ganglionic Acetylcholine Receptor Autoantibody: Labcorp test 085970

Labcorp test 085970, CPT 83519. Specimen: Serum. Turnaround: 7 - 10 days.

Ganglionic Acetylcholine Receptor Autoantibody is Labcorp test code 085970, billed with CPT 83519. Specimen: Serum. Turnaround time: 7 - 10 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: Quest Diagnostics, ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code085970
CPT83519
LOINC42233-7
SpecimenSerum
Volume1 mL
Minimum volume0.5 mL ( Note: This volume does not allow for repeat testing.)
ContainerRed-top tube or gel-barrier tube
Turnaround time7 - 10 days
Storage / transportRoom temperature

Also known as: AChR Ganglionic Neuronal Antibody; Ganglionic AChR (g-AChR) Autoantibody

Use

This test measures the level of ganglionic acetylcholine receptor autoantibody in serum.

Methodology

Ganglionic AChR (g-AChR) autoantibodies are measured by radio-immunoprecipitation as describe in several publications.

Collection instructions

If red-top tube is used, transfer separated serum to a plastic transport tube.

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated7 days
Frozen14 days
Freeze/thaw cyclesStable x3

Patient preparation

No isotopes administered 24 hours prior to venipuncture

Causes for rejection

Gross hemolysis; gross icterus; gross lipemia; plasma sample received; hyperproteinemia or hyperalbuminemia

Reference range

0.000–0.066 nmol/L

Limitations

This test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration. Although the finding of high levels of ganglionic AChR antibody is specific for the diagnosis of autoimmune autonomic ganglionopathy (AAG), a negative antibody test does not rule out the diagnosis. Ganglionic AChR antibodies, at lower levels, may be found in five percent to 10 percent of patients with other disorders that have limited autonomic dysfunction, including postural tachycardia syndrome, idiopathic gastrointestinal dysmotility or Lambert-Eaton myasthenic syndrome. These antibodies are not found in control subjects. The presence…

LOINC map

Result codeResult nameUnitsResult LOINC
085971Ganglionic AChRab, Serumnmol/L42233-7

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 83519

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation