Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › TORCH Antibodies, IgG

TORCH Antibodies, IgG: ARUP Laboratories test 0050772

ARUP Laboratories test 0050772, CPT 86644, 86694, 86762, 86777. Specimen: Serum separator tube (SST).. Turnaround: Within 24 hours.

TORCH Antibodies, IgG is ARUP Laboratories test code 0050772, billed with CPT 86644, 86694, 86762, 86777. Specimen: Serum separator tube (SST).. Turnaround time: Within 24 hours. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code0050772
CPT86644; 86694; 86762; 86777
LOINC27948-9, 5124-3, 8014-3, 8039-0
SpecimenSerum separator tube (SST).
Turnaround timeWithin 24 hours
Storage / transportRefrigerated.

Also known as: CMV Antibody IgG, HSV Type 1/2 Combined Ab, IgG; Rubella Antibody IgG; Torch panel; Toxoplasma gondii Ab, IgG

Use

Not recommended for diagnosing congenital infections in newborns; tests should be selected individually to target the most likely infectious agents. May be used in pregnant women to assess past exposure or immunization to Toxoplasma, Rubella, CMV, and HSV.

Methodology

Semi-Quantitative Chemiluminescent Immunoassay (CLIA)

Collection instructions

Allow specimen to clot completely at room temperature. Separate from cells ASAP or within 2 hours of collection. Transfer 2 mL serum to an ARUP standard transport tube. (Min: 1 mL) Parallel testing is preferred and convalescent specimens must be received within 30 days from receipt of the acute specimens.

Stability

After separation from cells: Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year (avoid repeated freeze/thaw cycles)

Causes for rejection

Refer to individual components.

Reference range

Test Number Components Reference Interval Rubella Antibody IgG <=8.9 Toxoplasma gondii Ab, IgG <=7.1 HSV Type 1/2 Combined Ab, IgG less than or equal to 0.89 CMV Antibody IgG 0.59 U/mL or less Not Detected 0.6 - 0.69 U/mL Indeterminate - Repeat testing in 10-14days may be helpful 0.70 U/mL or greater Detected

Remarks

Mark specimens plainly as "acute" or "convalescent."

Performed

Sun-Sat

Compliance Category

FDA

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
0050165CMV Antibody IgG5124-3
0050286HSV Type 1/2 Combined Ab, IgG27948-9
0050770Toxoplasma gondii Ab, IgG8039-0
0050771Rubella Antibody IgG8014-3

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 86644, 86694, 86762

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation