Rubella Antibodies, IgM: Labcorp test 096537
Labcorp test 096537, CPT 86762. Specimen: Serum. Turnaround: 1 - 3 days.
Rubella Antibodies, IgM is Labcorp test code 096537, billed with CPT 86762. Specimen: Serum. Turnaround time: 1 - 3 days. Performing laboratory: Labcorp, CLIA
34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
Test code096537
CPT86762
LOINC5335-5
SpecimenSerum
Volume0.5 mL
Minimum volume0.2 mL
ContainerRed-top tube or gel-barrier tube
Turnaround time1 - 3 days
Storage / transportRefrigerate. Specimen is stable for two days at room temperature and for seven days refrigerated. For storage longer than seven days, freeze the specimen.
Also known as: German Measles Specific IgM
Use
For the in vitro detection of IgM antibodies specific for rubella. IgM antibodies are associated with acute viral infections. IgM detection is useful in the following situations: evidence of infection can be obtained from only one acute phase specimen if the IgM results are positive; the IgM test can also be used to differentiate between primary infection and re-exposure. Rubella-specific IgM is found in virtually all infected patients by three weeks postdevelopment of a rash. Rubella-specific IgM is also found in 80% of postvaccination patients by three weeks. Congenitally infected infants will show an IgM response at 2 to 12 weeks postnatally.
Methodology
Chemiluminescent immunoassay (CLIA)
Causes for rejection
Hemolysis; lipemia; gross bacterial contamination
Reference range
• Negative: <20.0 AU/mL
• Equivocal: 20.0−24.9 AU/mL
• Positive: >24.9 AU/mL
Limitations
The absence of IgM at birth does not rule out congenital rubella since the frequency of IgM detection in cord blood decreases as the time between conception and fetal infection increases. Acquired rubella infection in infants is rare but must be considered if the blood is positive for IgM but was not obtained during the immediate postnatal period. Rubella-specific IgM may persist for months after an acute infection and, possibly, after vaccination as well. False-positive rubella IgM responses have been reported following mononucleosis, parvovirus B19 infections, and possibly other herpes-type viral infections. False-positive rubella IgM responses have also been reported in pregnant women.…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|
| 096539 | Rubella Antibodies, IgM | AU/mL | 5335-5 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 86762
- Measles, Mumps, Rubella (MMR) Immunity Profile
LabcorpTest code 058495CPT 86735, 86762, 86765SerumTAT 1 - 2 days
- MMRV Immunity
LabcorpTest code 263047CPT 86735, 86762, 86765, 86787Serum
- Occupation Screen - MMR/VZV Antibody Assessment Panel, IgG
ARUP LaboratoriesTest code 2011375CPT 86735, 86762, 86765, 86787Serum separator tube.TAT Within 24 hours
- Pregnancy, Initial Screening Profile
LabcorpTest code 144053CPT 81001, 85025, 86592, 86762, 86803, 86850, 86900, 86901, 87086, 87340, 87389, 87491, 87591Serum and whole blood and urine (UA/Culture) and endocervical swab, vaginal swabTAT 1 - 4 days
- Pregnancy, Initial Screening Profile With HBV Triple Panel
LabcorpTest code 144059CPT 81001, 85025, 86592, 86704, 86706, 86762, 86803, 86850, 86900, 86901, 87086, 87340, 87389, 87491, 87591Serum and whole blood and urine (UA/culture) and endocervical swab, vaginal swabTAT 1 - 4 days
- Pregnancy, Initial Screening Profile With HBV Triple Panel, VZV Immunity and QuantiFERON®-TB Gold Plus
LabcorpTest code 144099CPT 81001, 85025, 86480, 86592, 86704, 86706, 86762, 86787, 86803, 86850, 86900, 86901, 87086, 87340, 87389, 87491, 87591Serum and whole blood and urine (UA/culture) and endocervical swab, vaginal swabTAT 1 - 4 days
- Prenatal Infectious Disease Antibodies, Qualitative, IgG
LabcorpTest code 164101CPT 86644, 86695, 86696, 86762, 86777SerumTAT 1 - 3 days
- Rubella Antibodies, IgG
LabcorpTest code 006197CPT 86762SerumTAT 1 - 2 days
- Rubella Antibodies, IgG and IgM
ARUP LaboratoriesTest code 0050552CPT 86762Serum separator tube.TAT Within 24 hours
- Rubella Antibody, IgG
ARUP LaboratoriesTest code 0050771CPT 86762Serum separator tube (SST).TAT Within 24 hours
- Rubella Antibody, IgM
ARUP LaboratoriesTest code 0050551CPT 86762Serum separator tube (SST).TAT Within 24 hours
- Rubella IgG Antibody
Cleveland Clinic LaboratoriesTest code RUBIGGCPT 86762SerumTAT 1 - 4 days
- Rubella IgM Antibody
Cleveland Clinic LaboratoriesTest code RUBIGMCPT 86762SerumTAT 1 - 2 days
- TORCH Antibodies IgM
ARUP LaboratoriesTest code 3017749CPT 86645, 86762, 86778Serum separator tube (SST)TAT 1-2 days
- TORCH Antibodies, IgG
ARUP LaboratoriesTest code 0050772CPT 86644, 86694, 86762, 86777Serum separator tube (SST).TAT Within 24 hours
- Torch IgM Antibodies
Cleveland Clinic LaboratoriesTest code TORIGMCPT 86645, 86762, 86778SerumTAT Refer to individual components
- Pregnancy, Initial Screening Profile
LabcorpTest code 144053Women's HealthCPT 81001, 85025, 86592, 86762, 86803, 86850, 86900, 86901, 87086, 87340, 87389, 87491, 87591Serum and whole blood and urine (UA/Culture) and endocervical swab, vaginal swabTAT 1 - 4 days
- Rubella Antibodies, IgG
LabcorpTest code 006197Women's HealthCPT 86762SerumTAT 1 - 2 days
- Rubella Antibodies, IgM
LabcorpTest code 096537Women's HealthCPT 86762SerumTAT 1 - 3 days
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.