Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Tumor Necrosis Factor - alpha, Serum

Tumor Necrosis Factor - alpha, Serum: ARUP Laboratories test 0051539

ARUP Laboratories test 0051539, CPT 83520. Specimen: Serum separator tube, or plain red.. Turnaround: 1-4 days.

Tumor Necrosis Factor - alpha, Serum is ARUP Laboratories test code 0051539, billed with CPT 83520. Specimen: Serum separator tube, or plain red.. Turnaround time: 1-4 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp, Quest Diagnostics, Michigan Medicine Laboratories (MLabs).
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code0051539
CPT83520
LOINC3074-2
SpecimenSerum separator tube, or plain red.
Turnaround time1-4 days
Storage / transportCRITICAL FROZEN. Additional specimens must be submitted when multiple tests are ordered. Ship in an ARUP Standard Transport Tube.

Also known as: Cachectin; cytokine; cytokines; TNF Alpha; TNF-alpha; TNFa

Use

Primarily used for research and to support attempts to understand the pathogenesis of immune, infectious, allergic, or inflammatory disorders.

Methodology

Quantitative Multiplex Bead Assay

Collection instructions

CRITICAL FROZEN: Separate serum from cells within 2 hours of collection. Transfer 1 mL serum to an ARUP Standard Transport Tube. (Min: 0.4 mL) Freeze serum within 30 minutes.

Stability

After separation from cells: Ambient: 30 minutes; Refrigerated: Unacceptable; Frozen: 1 year

Causes for rejection

Refrigerated specimens. Contaminated or heat-inactivated specimens.

Reference range

Test Number Components Reference Interval Tumor Necrosis Factor - alpha, Serum 11.5 pg/mL or less

Performed

Sun-Sat

Compliance Category

Laboratory Developed Test (LDT)

New York DOH Approval Status

This test is New York state approved.

LOINC map

Result codeResult nameUnitsResult LOINC
0051539Tumor Necrosis Factor - alpha, Serum3074-2

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 83520

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation