Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › ARUP Laboratories › Herpes Simplex Virus Type 1 and/or 2 Antibodies, IgG (CSF) With Reflex to Type 1 and 2 Glycoprotein G-Specific Ab, IgG

Herpes Simplex Virus Type 1 and/or 2 Antibodies, IgG (CSF) With Reflex to Type 1 and 2 Glycoprotein G-Specific Ab, IgG: ARUP Laboratories test 3017747

ARUP Laboratories test 3017747, CPT 86694, 86695, 86696. Specimen: CSF. Turnaround: 1-2 days.

Herpes Simplex Virus Type 1 and/or 2 Antibodies, IgG (CSF) With Reflex to Type 1 and 2 Glycoprotein G-Specific Ab, IgG is ARUP Laboratories test code 3017747, billed with CPT 86694, 86695, 86696. Specimen: CSF. Turnaround time: 1-2 days. Performing laboratory: ARUP Laboratories, CLIA 46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp.
LaboratoryARUP Laboratories
CLIA number46D0523979
Test code3017747
CPT86694; if reflexed, add 86695; 86696
LOINC13249-8
SpecimenCSF
Turnaround time1-2 days
Storage / transportRefrigerated.

Also known as: glycoprotein type-specific reactivity; Herpes Simplex Antibodies, IgG CSF; Herpes Simplex CSF; HSV 1, 2 IgG CSF; HSV 1,2; HSV 1,2 and glycoprotein reflex; HSV 1,2 glycoprotein CSF; HSV CSF antibody; HSV glycoprotein G CSF; HSV glycoprotein G-based type-specific CSF

Use

Not recommended for herpes simplex virus (HSV) testing; lacks adequate predictive value for acute infection. Preferred testing is Herpes Simplex Virus (HSV-1/HSV-2) Subtype by PCR ( 2010095 ).

Methodology

Semi-Quantitative Chemiluminescent Immunoassay (CLIA) / Semi-Quantitative Enzyme-Linked Immunosorbent Assay (ELISA)

Collection instructions

Transfer 1 mL CSF to an ARUP standard transport tube. (Min: 0.5 mL)

Stability

Ambient: 8 hours; Refrigerated: 2 weeks; Frozen: 1 year

Causes for rejection

Specimen types other than CSF. Contaminated, heat-inactivated, icteric, or hemolyzed specimens.

Reference range

Test Number Components Reference Interval HSV 1/2 Antibody Screen IgG, CSF 0.89 IV or less

Performed

Sun-Sat

Compliance Category

Laboratory Developed Test (LDT)

New York DOH Approval Status

This test is not New York state approved. The performing laboratory will submit an NYDOH Single Use Permit (SUP) upon receipt of order. If SUP is approved by NYDOH, testing will be performed.

LOINC map

Result codeResult nameUnitsResult LOINC
0050394HSV 1/2 Antibody Screen IgG, CSF13249-8

View this test on ARUP Laboratories's website → · Last checked 2026-11-29

Other tests billed with CPT 86694, 86695, 86696

Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation