Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › Protime/INR

Protime/INR: Allina Health Laboratory (Abbott Northwestern) test 487

Allina Health Laboratory (Abbott Northwestern) test 487, CPT 85610. Specimen: Sodium citrate (Na cit) whole blood. Turnaround: 1 day.

Protime/INR is Allina Health Laboratory (Abbott Northwestern) test code 487, billed with CPT 85610. Specimen: Sodium citrate (Na cit) whole blood. Turnaround time: 1 day. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Labcorp, ARUP Laboratories, OHSU Laboratory Services, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code487
CPT85610; Subject to medical necessity (Y/N):; Yes; LCD/NCD:; Medical necessity
LOINC—
SpecimenSodium citrate (Na cit) whole blood
Volume2.7mL
ContainerLt blue Sodium citrate (Na Cit) - 2.7mL If the patient has a hematocrit >55, a specially prepared Lt blue Sodium citrate (NaCit) tube must be used in place of the standard Lt blue Sodium citrate (NaCit) tube. Hematocrit-Anticoagulant adjustments
Turnaround time1 day

Also known as: PT; Prothrombin time

Use

A basic coagulation screening test for the assessment of congenital and acquired deficiencies of the extrinsic pathway (factors II, V, VII, X). The Prothrombin time can be prolonged in certain clinical states, i.e. warfarin therapy, intestinal reabsorption disorders, liver failure, fibrinolysis and DIC To monitor warfarin therapy

Methodology

Clot Based Assay

Collection instructions

Do not over or under fill tube as the ratio of anticoagulant to whole blood is critical Coag – tube fill guidelines If the patient has a hematocrit >55, a specially prepared Lt blue Sodium citrate (NaCit) tube must be used in place of the standard Lt blue Sodium citrate (NaCit) tube. Refer to the Collection container for instructions. Immediately following collection, mix sample thoroughly by gently inverting 8 - 10 times to prevent clotting

Stability

Whole blood: Ambient - 24 hrs Plasma: Frozen (OK)

Causes for rejection

Greiner tubes are not acceptable Improper labeling (unlabeled or mislabeled) Improper anticoagulant Improperly filled tube Hemolysis Clotted specimen Delay in transport Improper storage/transport temperature

Reference range

Protime: 10.6 - 13.0 seconds INR: Age Range 0-2 months 0.53-1.3 3-6 months 0.6-1.2 Adult ≤1.2 Therapeutic (most patients) 2.0-3.0 Therapeutic (high risk patients) 2.5-3.5 Results that require action (critical): 0 - 28 days: > 1.3 >28 days: > 6.0

Performed

Daily

Abbreviation

PT

Order number

85610.0

Alternate specimens

Sodium citrate (Na cit) plasma Alternate processing instructions: If the sample will not reach the AHL Central Laboratory within 24 hours: Process Platelet Poor Plasma (P.P.P) Coag – how to prepare a specimen for special coagulation testing Transfer plasma into an aliquot tube using a spot label "NaCit Plasma P.P.P" to label as platelet poor plasma Freeze immediately Alternate transport container: Microcentrifuge vial/tube in a Snap cap conical vial/tube and cap (Beaker sites) Coagulation specimen transport vial/tube (all other sites)

Transport container

Lt blue Sodium citrate (Na Cit) - 2.7mL tube

Performing Laboratory

AHL - Coagulation: W

Processing instructions

Test must be run within 24 hours of collection.

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 85610

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation