Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Chlamydia trachomatis, TMA (Alternate Target), Rectal

Chlamydia trachomatis, TMA (Alternate Target), Rectal: Quest Diagnostics test 91046

Quest Diagnostics test 91046, CPT 87491. Specimen: 1 rectal swab submitted in Aptima® Multitest transport tube.

Chlamydia trachomatis, TMA (Alternate Target), Rectal is Quest Diagnostics test code 91046, billed with CPT 87491. Specimen: 1 rectal swab submitted in Aptima® Multitest transport tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, Allina Health Laboratory (Abbott Northwestern), ARUP Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code91046
CPT87491
LOINC—
Specimen1 rectal swab submitted in Aptima® Multitest transport tube
Minimum volume1 rectal swab submitted in Aptima Multitest transport tube
ContainerAptima Multitest transport tube (orange label)
Storage / transportRoom temperature

Methodology

Transcription-Mediated Amplification (TMA)

Collection instructions

Use the Aptima Multitest transport tube (orange label). Insert swab approximately 3-5 cm into the rectum. Rotate swab against the rectal wall at least 3 times. Withdraw the swab carefully. Swabs that are grossly contaminated with feces should be discarded and the collection repeated. Remove the cap from the swab specimen transport tube and immediately place the swab into the transport tube. Carefully break the swab shaft at the score line. Re-cap the swab specimen transport tube tightly, label and ship to the lab.

Stability

TemperaturePeriod
Room temperature30 days
Refrigerated30 days
Frozen30 days

Causes for rejection

Transport tubes with 2 swabs • Transport tubes with non-Aptima® swabs • Transport tubes with no swab • Specimens in broken containers • Swabs submitted in VCM/UTM or M4 viral transport

Reference range

Not detected

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Alternative specimen(s)

Aptima Unisex Swab Specimen Collection Kit (white label)

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 87491

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation