Sound Lab Consultants › National Lab Test Directory › Labcorp › Chlamydia/Gonococcus − Client-provided Aliquot

Chlamydia/Gonococcus − Client-provided Aliquot: Labcorp test 186200

Labcorp test 186200, CPT 87491, 87591. Specimen: PreservCyt® fluid (removed prior to processing of the vial on the ThinPrep® processor) placed in the Gen-Probe® Aptima® . Turnaround: 2 - 3 days.

Chlamydia/Gonococcus − Client-provided Aliquot is Labcorp test code 186200, billed with CPT 87491, 87591. Specimen: PreservCyt® fluid (removed prior to processing of the vial on the ThinPrep® processor) placed in the Gen-Probe® Aptima® swab transport tube. Turnaround time: 2 - 3 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code186200
CPT87491; 87591
LOINC45068-4, 50387-0, 50388-8
SpecimenPreservCyt® fluid (removed prior to processing of the vial on the ThinPrep® processor) placed in the Gen-Probe® Aptima® swab transport tube
Volume1 mL; although up to 4 mL may be removed from the ThinPrep® vial, only 1 mL of PreservCyt® will be placed in the transport device
Minimum volume1 mL PreservCyt®
ContainerGen-Probe® Aptima® swab transport or Gen-Probe® Aptima® specimen transfer kit with 1 mL of PreservCyt® fluid (do not use swabs provided with Aptima® kit)
Turnaround time2 - 3 days
Storage / transportMaintain specimen at room temperature or refrigerate (2°C to 30°C). Aliquots must be transferred to the Aptima® tube within seven days of collection.

Use

Detect Chlamydia trachomatis and/or Neisseria gonorrhoeae

Methodology

Nucleic acid amplification (NAA)

Collection instructions

ThinPrep® preservative vial processing: ThinPrep® instructions for removal of material are specifically listed in the ThinPrep® 2000 and ThinPrep® 3000 System Operator's manual Addenda. These instructions include the following statement. “Good laboratory practices should be followed to avoid introducing contaminants into either the PreservCyt® sample vial (ThinPrep® vial) or the aliquot. It is recommended to use powder-free gloves and an individually wrapped, disposable pipetting device with an aerosol barrier tip that is sized appropriately for the volume being withdrawn and dispensed. You should not use serological pipettes. In order to minimize the potential for cross contamination, aliquot removal should be performed in an appropriate location outside an area where amplification is performed.” LabCorp uses the following procedure and believes it is consistent with the previous instructions as well as with the amplified assay that will be performed on the specimen to be sent. Note: For testing, aliquots must be transferred to Aptima® specimen transport tubes or Aptima® Unisex specimen transport tubes (both referred to as “Aptima® tube” in the following procedure) from ThinPrep® vials within seven days of specimen collection when ThinPrep® vials are stored at 15°C to 30°C. Aliquot Removal Procedure 1. Put on clean gloves. 2. Wipe down work surfaces and pipettors with 1:1 bleach:water solution. 3. Allow bleach to contact work surfaces and pipettors for at least one minute and then follow with a water rinse. 4. Cover the bench with clean, plastic-backed absorbent laboratory bench covers. 5. Retrieve ThinPrep® vials that are to have aliquots removed. 6. In the specimen transfer area, place a test tube rack containing a sufficient number of Aptima® tubes to the number of ThinPrep® Pap specimens being tested for Ct/Ng. 7. Label each Aptima® tube with the appropriate specimen label. 8. Put on clean gloves before proceeding to specimen transfer. 9. Loosen the cap on the Aptima® tube. Be sure not to touch the pierceable foil cap of the Aptima® tube. 10. Vortex the ThinPrep® vial for 8 to 12 seconds at high speed. Caution: The desired aliquot must be removed immediately after vortexing the vial to ensure homogeneity of the sample. 11. Uncap the vial and place it on the work surface with the threads facing up. 12. Using a pipetting device with an aerosol barrier tip, immediately withdraw a 1 mL aliquot from the ThinPrep® vial. 13. Uncap the Aptima® tube and retain the cap in your hand. 14. Carefully dispense the aliquot into the appropriately labeled Aptima® tube. 15. Recap the Aptima® tube tightly. Gently invert the tube two to three times to ensure complete mixing of the specimen. 16. Dispose of the pipette tip into a biohazard bag containing absorbent material soaked with bleach. 17. Recap the ThinPrep® Liquid Pap specimen for Pap smear processing. 18. Store the aliquot in Aptima® tube at 15°C to 30°C for transport to LabCorp. 19. Put on clean gloves

Causes for rejection

Gen-Probe Pace® transport system; bacterial swab specimen; transport with multiple swabs; specimen received in grossly leaking transport container; specimen submitted in fixative or additives; specimen received in expired transport media or incorrect transport device; inappropriate specimen transport conditions; specimen received after prolonged delay in transport (usually more than 72 hours); swab in transport device; unlabeled specimen or name discrepancy between specimen and request label; prequot specimens with more than 1 mL of PreservCyt® added

Reference range

Negative; no Chlamydia trachomatis or Neisseria gonorrhoeae detected.

Special instructions

Specimens submitted for this test must be handled using precautions necessary to prevent cross-contamination. This training should be provided by Hologic.

Limitations

“Because cytology/HPV testing and STD testing address different clinical questions, aliquot removal may not be suitable for all clinical situations. Physicians and other persons responsible for ordering clinical tests should be familiar with the following. • There is no evidence of degradation of cytology results by aliquot removal, however, this cannot be ruled out for all specimens. As with any subsampling step in anatomic pathology, chance misallocation of diagnostic cells may occur if they are very rare. If negative results from the specimen do not fit with the clinical impression, a new specimen may be necessary. • Aliquot removal from low-cellularity may leave insufficient material in…

LOINC map

Result codeResult nameUnitsResult LOINC
186201Chlamydia Prequot, NAA50387-0
186202Gonococcus Prequot, NAA50388-8

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87491, 87591

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation