Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Labcorp › Chlamydia/Gonococcus/Trichomonas vaginalis/Mycoplasma genitalium (With Reflex to Macrolide Resistance), NAA, Urine

Chlamydia/Gonococcus/Trichomonas vaginalis/Mycoplasma genitalium (With Reflex to Macrolide Resistance), NAA, Urine: Labcorp test 180107

Labcorp test 180107, CPT 87491, 87563, 87591, 87661. Specimen: First-void urine in Aptima® urine transport. Turnaround: 3 - 4 days.

Chlamydia/Gonococcus/Trichomonas vaginalis/Mycoplasma genitalium (With Reflex to Macrolide Resistance), NAA, Urine is Labcorp test code 180107, billed with CPT 87491, 87563, 87591, 87661. Specimen: First-void urine in Aptima® urine transport. Turnaround time: 3 - 4 days. Performing laboratory: Labcorp, CLIA 34D0655059 (Burlington, NC). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories.
LaboratoryLabcorp
CLIA number34D0655059
Test code180107
CPT87491; 87563; 87591; 87661
LOINC100703-8, 60256-5
SpecimenFirst-void urine in Aptima® urine transport
Volume2 mL aliquot of a 20-to-30 mL urine collection
Minimum volume2 mL aliquot of a 20-to-30 mL urine collection
ContainerAptima® Urine
Turnaround time3 - 4 days
Storage / transportMaintain specimen at room temperature or refrigerate (2°C to 30°C).

Use

This test is used to detect the presence of Chlamydia trachomatis, Neisseria gonorrhoeae, Trichomonas vaginalis and Mycoplasma genitalium rRNA in urine specimens. If M. genitalium is detected, additional testing for macrolide resistance determination will be performed.

Methodology

Nucleic Acid Amplification (NAA)

Collection instructions

The patient should not have urinated for at least one hour prior to specimen collection. Direct patient to provide a first-catch urine (approximately 20 mL to 30 mL of the initial urine stream) into a urine collection container free of any preservatives. Collection of larger volumes of urine may result in specimen dilution that may reduce test sensitivity; lesser volumes may not adequately rinse organisms into the specimen. Female patients should not cleanse the labial area prior to providing the specimen. Add urine to the Aptima® urine collection device. The final volume must be between the two black lines on the device (about 2 mL).

Stability

TemperaturePeriod
Room temperature30 days (stability provided by manufacturer or literature reference)
Refrigerated30 days (stability provided by manufacturer or literature reference)

Patient preparation

The patient should not have urinated for at least one hour prior to specimen collection.

Causes for rejection

Specimen with incorrect patient identification; unlabeled specimen; inappropriate specimen transport conditions; specimens received after prolonged delay (usually >72 hours); specimen leaked in transit; specimen in expired transport or incorrect transport device; specimens with inappropriate source for test requested; specimen with fixative or additives; Aptima® urine transport >30 days from collection; Aptima® urine transport with incorrect specimen volume; specimen in ProbeTec™ UPT transport; ProbeTec™ Q-swabs; urine in sterile container

Special instructions

If reflex test is performed, additional charges/CPT code(s) may apply.

Limitations

A negative result does not preclude a possible infection. Test results may be affected by improper specimen collection or target levels below the assay limit of detection (LoD). Results from this testing should be interpreted in conjunction with other clinical and laboratory data available to the clinician. Reliable results are dependent on adequate specimen collection, transport, storage and processing. Failure to observe proper procedures in any one of these steps can lead to incorrect results. The macrolide resistance reflex test was developed and its performance characteristics determined by Labcorp. It has not been cleared or approved by the Food and Drug Administration. The FDA has…

LOINC map

Result codeResult nameUnitsResult LOINC
Ct/GC/Tv/Mg Rflx MacRes NAA Ur180052Neisseria gonorrhoeae, NAA60256-5
Ct/GC/Tv/Mg Rflx MacRes NAA Ur180086Mycoplasma genitalium NAA100703-8

View this test on Labcorp's website → · Last checked 2026-11-29

Other tests billed with CPT 87491, 87563, 87591

Search the National Lab Test Directory · All Labcorp tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation