Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Antithrombin III Activity with Reflex to Antithrombin III Antigen

Antithrombin III Activity with Reflex to Antithrombin III Antigen: Quest Diagnostics test 8267

Quest Diagnostics test 8267, CPT 85300. Specimen: 1 mL frozen platelet-poor plasma collected in each of two 3.2% sodium citrate (light blue-top) tubes.

Antithrombin III Activity with Reflex to Antithrombin III Antigen is Quest Diagnostics test code 8267, billed with CPT 85300. Specimen: 1 mL frozen platelet-poor plasma collected in each of two 3.2% sodium citrate (light blue-top) tubes. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code8267
CPT85300
LOINC—
Specimen1 mL frozen platelet-poor plasma collected in each of two 3.2% sodium citrate (light blue-top) tubes
Minimum volume0.5 mL each specimen
ContainerTransport tube(s)
Storage / transportFrozen

Also known as: AT3; Heparin Cofactor; AT III

Methodology

Chromogenic Substrate

Collection instructions

Please submit a separate, frozen vial for each special coagulation assay ordered. Draw blood in a light blue-top tube containing 3.2% sodium citrate, mix gently by inverting 3-4 times. Centrifuge 15 minutes at 1500 g within one hour of collections. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial(s). Freeze immediately and transport on dry ice.

Stability

TemperaturePeriod
Room temperatureUnacceptable
RefrigeratedUnacceptable
Frozen30 days

Causes for rejection

Gross hemolysis • Grossly lipemic • Grossly icteric

Notices

Not offered in Quest Diagnostics Nichols Institute (IFD) – San Juan Capistrano. Please provide Service area information to confirm Test Code for the lab that services your account or to find available tests you can order.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 85300

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation