Antithrombin (AT) Deficiency Profile: Labcorp test 015594
Labcorp test 015594, CPT 85300, 85301. Specimen: Plasma, frozen. Turnaround: 2 - 3 days.
Test includes
This test includes antithrombin activity and antithrombin antigen.
Use
This test is used for confirmation and characterization of congenital AT deficiency.
Methodology
AT antigen: Automated (LIATEST) enzyme immunoassay (EIA) AT activity: The patient plasma is mixed with heparin and thrombin. The extent of thrombin inhibition is proportional to the AT concentration of the patient sample. Residual thrombin activity is measured as the rate of conversion of a chromogenic substrate and is used to calculate AT concentration.
Collection instructions
Citrated plasma samples should be collected by double centrifugation. Blood should be collected in a blue-top tube containing 3.2% buffered sodium citrate. Evacuated collection tubes must be filled to completion to ensure a proper blood to anticoagulant ratio. The sample should be mixed immediately by gentle inversion at least six times to ensure adequate mixing of the anticoagulant with the blood. A discard tube is not required prior to collection of coagulation samples, except when using a winged blood collection device (ie, "butterfly"), in which case a discard tube should be used. When noncitrate tubes are collected for other tests, collect sterile and nonadditive (red-top) tubes prior to citrate (blue-top) tubes. Any tube containing an alternate anticoagulant should be collected after the blue-top tube. Gel-barrier tubes and serum tubes with clot initiators should also be collected after the citrate tubes. Centrifuge for 10 minutes and carefully remove / 3 of the plasma using a plastic transfer pipette, being careful not to disturb the cells. Deliver to a plastic transport tube, cap, and recentrifuge for 10 minutes. Use a second plastic pipette to remove the plasma, staying clear of the platelets at the bottom of the tube. Transfer the plasma into a Labcorp PP transpak frozen purple tube with screw cap (Labcorp No. 49482). Freeze immediately and maintain frozen until tested. Please print and use the Volume Guide for Coagulation Testing to ensure proper draw volume.
Patient preparation
Do not draw from an arm with a heparin lock or heparinized catheter. Ideally, patients should not be on unfractionated heparin or direct Xa inhibitor therapy.
Causes for rejection
Severe hemolysis; improper labeling; clotted specimen; specimen diluted with IV fluids; samples thawed in transit; improper sample type; sample out of stability
Reference range
In newborns, AT levels are lower than in adults (39% to 89%). Levels gradually reach adult ranges by six months of age.
Special instructions
If the patient's hematocrit exceeds 55%, the volume of citrate in the collection tube must be adjusted. Refer to Coagulation Collection Procedures for directions.
Limitations
AT testing should not be performed on patients on heparin therapy because heparin decreases plasma AT levels. AT results for individuals on warfarin therapy should be interpreted with caution because warfarin can increase levels of AT of patients with heterozygous deficiency into the normal range. Thrombin inhibitors, such as dabigatran, hirudin, and argatroban, interfere with the AT activity assay when it is based on thrombin inhibition. Direct Xa anticoagulant will interfere with the assay when it is based on inhibition of Xa causing it to be falsely, elevated possibly masking a deficiency.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| Antithrombin Activity | % | 27811-9 | |
| Antithrombin Antigen | % | 27812-7 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 85300, 85301
- Antithrombin (AT) Activity
- Antithrombin Assay
- Antithrombin Panel
- Antithrombin, Enzymatic (Activity)
- ATIII Antigen
- DIC Panel
- Disseminated Intravascular Coagulation (DIC) Profile, Comprehensive Plus
- Hypercoagulation Diagnostic Interpretive Panel
- Thrombotic Risk Assessment
- Thrombotic Risk Reflex Panel
- Thrombotic Risk, Congenital
- Thrombotic Risk, Congenital (Extended)
- Antithrombin (AT) Deficiency Profile
- Antithrombin (AT) Antigen (Immunologic)
- Antithrombin, Antigen
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation