Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Antithrombin III Activity

Antithrombin III Activity: Michigan Medicine Laboratories (MLabs) test AT3

Michigan Medicine Laboratories (MLabs) test AT3, CPT 85300. Specimen: Full 2.7mL tube or 1 mL plasma aliquot. Turnaround: 1 hour.

Antithrombin III Activity is Michigan Medicine Laboratories (MLabs) test code AT3, billed with CPT 85300. Specimen: Full 2.7mL tube or 1 mL plasma aliquot. Turnaround time: 1 hour. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories, Quest Diagnostics, ARUP Laboratories.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeAT3
CPT85300
LOINC—
SpecimenFull 2.7mL tube or 1 mL plasma aliquot
VolumeFull 2.7mL tube or 1 mL plasma aliquot
Turnaround time1 hour
Storage / transportRoom temperature for whole blood or frozen aliquot of citrated plasma.

Also known as: Antithrombin III Assay, Functional; Serine Protease Inhibitor; Factor 10a Inhibition

Use

AT3 levels are used as a possible indicator of hypercoagulability, and to test for the hereditary deficiency of antithrombin. AT3 levels might also be of use in cases of suspected heparin failure especially prior to heparinization.

Collection instructions

Collect specimen in a blue top (citrate 3.2%) tube. Mix by inversion. Specimen should arrive at lab within 3 hours of collection; transport at room temperature. Alternatively, centrifuge, aliquot plasma into a plastic vial, and freeze the specimen within 4 hours of collection. Transport frozen specimen on dry ice. Collection of the blood through lines that have been previously flushed with heparin should be avoided. If the blood must be drawn through a VAD (vascular access device), the line should be flushed with 5 mL of saline and the first 5 mL of blood or six dead space volumes of the VAD discarded.

Reference range

75 - 125%

Limitations

If a patient is on heparin therapy or has received heparin within the last 10 days, the results of this test may be falsely decreased. The AT3 level may be diminished for several days after surgery or a thrombotic event. Warfarin therapy has been reported to raise AT3 levels.

Section

Coagulation

Performed

Tuesday

Contraindications

Test is not indicated for patients on heparin, low-molecular-weight heparin, or direct thrombin inhibitor therapy. This test is not indicated for inpatient evaluation of acute thrombosis.

NY State approved

No

Performing Laboratory

Clinical Core Laboratory

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 85300

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation