Quest Diagnostics test 7085, CPT 82040, 82042, 82784, 83873, 83916. Specimen: 4.2 mL CSF and 3 mL serum.

Multiple Sclerosis Panel 2 is Quest Diagnostics test code 7085, billed with CPT 82040, 82042, 82784, 83873, 83916. Specimen: 4.2 mL CSF and 3 mL serum. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Allina Health Laboratory (Abbott Northwestern), Labcorp, OHSU Laboratory Services, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code7085
CPT82040, 82042, 82784 (x2), 83873, 83916
LOINC—
Specimen4.2 mL CSF and 3 mL serum
Minimum volume2 mL CSF • 1.5 mL serum
Container⁠⁠⁠⁠⁠⁠⁠CSF: Sterile plastic CSF vial Serum: Transport tube
Storage / transportRefrigerated (cold packs)

Also known as: MS

Methodology

Isoelectric Focusing (IEF) • Nephelometry • Radioimmunoassay (RIA)

Collection instructions

Please see the individual tests for specific specimen requirements and stabilities. Both CSF & serum are required specimens. It is preferred that the collection date and time be the same for both; however, it is acceptable for them to be drawn within 48 hours of each other. If no serum is supplied, the client will be contacted to confirm the order. CSF collection tube #4 is preferred. Submitting 4th lumbar puncture collection tube minimizes blood contamination. Transport temperature: Refrigerate CSF specimens at 2-8° C in sterile plastic CSF vial(s) and send refrigerated (cold packs) to the laboratory OR freeze CSF specimens at -20° C and send frozen samples to the laboratory on dry ice.

Stability

TemperaturePeriod
Room temperature8 hours
Refrigerated7 days
Frozen21 days

Causes for rejection

Hemolysis • Xanthochromia/RBCs in CSF

Reference range

See Laboratory Report

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 82040, 82042, 82784

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation